[DB600] General instruction manual
- 142 -
9-2
Parameter list
Screen
Item
Setting range
Default
Operation PV (measured value)
to
[°C]
: Over-range
: Under-range
SV (setting value)
to
[°C]
□□□
Step time
to
[Hour : Minute]
□□
Output 1 value
to
[%]
Output 2 value
to
[%]
AUTO/
MANUAL switch
□
: AUTO output
: MANUAL output
□
Event status
: All events OFF
□□
to
: All events ON
: Alarm event reset
Timer 1 elapsed time display
to
[sec]
□□□□
Timer 2 elapsed time display
to
[sec]
□□□□
CT measured value display
to
[A]
: Measured value not obtained
□
FB setting value display
to
[%]
□□□
PID
auto tuning
□□
: Tuning not executed/forced to
terminate
: PID tuning for output 1 started
: PID tuning for output 2 started
: Tuning step 1
□□
to
: Tuning step 4
□□
FB tuning
□□
: Tuning not executed/forced to
terminate
: FB tuning started
□
□
: FB tuning at zero side
□
□
: FB tuning at span side
Pattern repeat remaining
number display
to
[time]
□□□□
RUN/READY
switch
□□
: RUN status
: READY status
□□
Execution No. selection for
constant value operation
to
□□
Pattern No. selection
to
□□
Program drive
: Program operation RESET
□□
: Program operation RUN
□
: Program operation STOP
□□
: Program operation ADVANCE
□□
: Program operation END
MODE 0 Executing SV
to
[°C]
□□□
Executing step time
to
[Hour : Minute]
□□
Executing event 1
to
Executing event 2
to
Executing event 3
to
Executing event 4
to
Executing P
: Two-position control
to
[%]
□□□
Executing I
to
[sec]
□□□
Executing D
to
[sec]
□□□
Executing output limiter L
to
[%]
□□□
Executing output limiter H
□
to
[%]
□
Executing guaranty soak
: Function OFF
to
[°C]
□□□
MODE 1 SV rate of change for rise
: Function OFF
to
[°C]
□□□
SV rate of change for fall
: Function OFF
to
[°C]
□□□
SV rate of change unit
□
: Second
□
: Minute
: Hour
□□
Constant value operation
PV start
: SV start (PV start OFF)
: PV start
□□□
Alarm action
at READY
: Alarm event not calculated in
READY status
□
: Alarm event calculated in READY
status
□□
MODE 2 Program/
constant value
operation switch
: Constant value operation (program
operation OFF)
□
: Program operation (program
operation ON)
□□□
Program operation
time unit
□
: [Hour : Minute]
□
: [Minute : Second]
□□
□
SV in RESET
to
[°C]
□□□
Pattern repeat
to
[time]
□□□□
Operation screen
time display
□
: Step elapsed time
: Step remaining time
□
Pattern clear
□
: No pattern clear
: Initialize pattern No. 1
□□
to
: Initialize pattern No. 4
□
: Initialize all patterns
□□
Screen
Item
Setting range
Default
Pattern copy
□
: No pattern copy
: Copy pattern No. 1 to No. 2
□□
to
: Copy pattern No. 4 to No. 3
□□
Number of steps
to
: No step
to
: 1 to 12 steps
□□□□
Program operation PV
start
: SV start (PV start OFF)
: PV start
□□□
Start SV
to
[°C]
□□□
SV for program
operation
to
[°C]
□□□
Step time
to
[H:M, M:S]
□□
Execution No. selection
for program operation
□
: Keep the previous No.
□
to
□□
(STEP1)
□□
(other than
STEP1)
Output 1
at END
: Constant value operation (AUTO output)
to
[%]
□
Output 2
at END
: Constant value operation (AUTO output)
to
[%]
□
Linked
pattern No.
: No link
: Pattern No. 1
□
to
: Pattern No. 4
□□
MODE 3 SV for constant value
operation (8 types)
to
[°C]
□□□
Event 1 (8 types)
to
Event 2 (8 types)
to
Event 3 (8 types)
to
Event 4 (8 types)
to
P (8 types)
: Two-position control
to
[%]
□□□
I (8 types)
to
[sec]
□□□
D (8 types)
to
[sec]
□□□
Output limiter L (8 types)
to
[%]
□□□
Output limiter H (8 types)
□
to
[%]
□
Guaranty soak (8 types)
: Function OFF
to
[°C]
□□□
MODE 4 Event mode
□□
: No event
□
: Absolute value upper limit alarm
□
: Absolute value lower limit alarm
□
: Deviation upper limit alarm
□
: Deviation lower limit alarm
□
: Absolute value deviation upper
limit alarm
□
: Absolute value deviation lower
limit alarm
□
: Setting value upper limit alarm
□
: Setting value lower limit alarm
□
: Output value upper limit alarm
□
: Output value lower limit alarm
□
: Heater upper limit alarm
□
: Heater lower limit alarm
: Timer 1 alarm
: Timer 2 alarm
□
: FAIL alarm
□
: Constant value operation RUN status
: Preset manual status
□□
: Remote input status
□
: SV rising status
□
: SV falling status
□
: Step switch status in program operation
□
: Step 1 status in program operation
□□
to
: Step 12 status in program operation
□
: Program operation RUN status
□
: Program operation STOP status
□□
: Program operation ADVANCE status
: Program operation RESET status
□□
: Program operation END status
: SV constant status in program
operation
□□
(EV1, EV3)
□□
(EV2, EV4)
□□
(EV5 to
EV9)
Event extension
function
□□
: No extension function
□
: Event standby
□
: Event keep
: Event standby/keep
□□
Event dead band
to
□□
Event output phase
: Normal phase output
: Reverse phase output