INST.No.INE-475-P1CE Software Version 1.00
-42-
10.2.6 Air-cooling box IR-WEX
It is used to protect the detector unit from dusts and cool the detector unit by air. (The detector unit is
housed in this air-cooling box.)
Working temperature
0 to 55
°
C
Material Air-cooling
portion:
SUS304
Mounting metal portion: Iron
Air
Flow: 100 to 500N
ℓ
/min
Weight About
14kg
10.2.7 Relaying box IR-WEE
It is used as a relaying terminal for the multiple-detector-units connection and a power unit is built in.
The steel case and the SUS case are available. The SUS case is the splash-proof construction.
IR-WEE1 IR-WEE2
Working temperature range
0 to 50°C
0 to 50°C
Material Steel
SUS304
Color
5Y7/1 (light beige)
-
Weight Approx.
4kg
(including the power unit)
Approx. 4kg
(including the power unit)