6. Inverter Status
This inverter is designed to be user-friendly; therefore, the status of the
Inverter can be easily understood by reading the information shown on the
front panel display. All possible messages are shown in the following table.
Display information
Operating
conditions
In English
In German
Description
Normal Working Status
Power off
No display
No display
In case of input
voltage < 200V, PV
inverter is totally
shutdown
Standby
Status: Standby Status: Standby
Input voltage range:
200V~ 260V
Initialization &
waiting
Status: Waiting Status: Warten
Input voltage range:
260~350V
Check grid
Status: Checking
xxxs
Status: Netz-Prüf
xxxs
In case of PV voltage
> 350V, inverter is
checking feeding
conditions
Feeding grid,
MPPT
Status:
Normal
Status:
Normalbetriebe
Inverter is feeding
power. After 10
seconds of this
display, LCD will show
wattage.
Waiting for
reconnect to grid
Status:
Reconnect xxxs
Status: Kontakt
xxxs
The time for reconnect
to grid
FLASH
Status: FLASH
Status: FLASH
FLASH firmware
SLAVE FLASH
Status: SLAVE
FLASH
Status: SLAVE
FLASH
SLAVE FLASH
firmware