Page 56 Copyright CPS America Co., Ltd.
9. Maintenance
9.1 Replace the external cooling fan
For
CPS SCE4KTL-O/US and CPS SCE5KTL-O/US
models, there is no
cooling fan designed for the external housing, but an internal fan designed in
PV inverter for the thermal management. Therefore,
“FAN Lock”
is the only
failures message that user will receive from the LCD if the operation of
internal cooling fan has failed. If this situation happens, please contact our
after-sales service center for further instructions.
For
CPS SCE6KTL-O/US and CPS SCE7KTL-O/US
models, there is an
external cooling fan and the internal cooling fan designed in PV inverter for
the thermal management.
The external fan is located at the top of PV Inverter as shown in figure 9.1.2.
When the cooling fan is not working properly, user will receive three different
kinds of failure messages from the LCD.
1.
“FAN Lock”
is the first kind of failure message that will be shown on the
LCD when both external and internal cooling fans are not working properly.
2.
“FAN1 Lock”
is the second kind of failure message when the external
cooling fan is not working properly.
3.
“FAN2 Lock”
is the third kind of failure message when the internal cooling
fan is not worked properly.
If
“FAN1 Lock” is indicated on the
CPS SCE6KTL-O/US
and
CPS
SCE7KTL-O/US models, please check whether there is any obstacle
(stopping) blocking the external fan.
When no obstacle is found, users can
follow the procedures to change the external cooling fan to see whether the
cooling fan problem can be fixed by changing a new cooling fan. If the
“
FAN
Lock
” or “
FAN2 Lock
” is indicated on the CPS SCE6KTL-O/US and CPS
SCE7KTL-O/US models, please contact our after-sales service center for
further instructions since the internal cooling fan is not working properly.
IMPORTANT
If the
“
FAN2 LOCK
” is indicated on the CPS SCE6KTL-O/US and
CPS SCE7KTL-O/US models or
“
FAN LOCK
” on the CPS
SCE4KTL-O/US and CPS SCE5KTL-O/US models, this means
the interior cooling fan inside the main housing of PV Inverter is
probably defective and needs to be replaced. Please contact our