background image

07

9

.

1

 

Environmental

 

Protection

   

In

 

order

 

to

 

protect

 

the

 

environment

the

 

product

 

or

 

product

 

parts

 

should

 

be

 

disposed

 

of

 

according

 

to

 

the

 

industrial

 

waste

 

treatment

 

process

or

 

be

 

sent

 

to

 

the

 

recycling

 

station

 

for

 

assortment

dismantling

 

and

 

recycling

 

according

 

to

 

local

 

regulations

.

9

.

2

 

Warranty

 

period

        

The

 

warranty

 

period

 

of

 

the

 

product

 

is

 

30

 

months

 

from

 

production

 (

delivery

date

 

if

 

the

 

product

 

is

 

kept

 

under

 

normal

 

storage

 

conditions

 

and

 

the

 

package

 

or

 

the

 

product

 

itself

 

is

 

in

 

good

 

condition

If

 

the

 

warranty

 

period

 

has

 

expired

please

 

inspect

 

the

 

product

 

and

 

make

 

sure

 

it

 

meets

 

all

 

the

 

requirements

 

before

 

installing

 

and

 

using

 

the

 

product

The

 

following

 

circumstances

 

are

 

not

 

within

 

the

 

scope

 

of

 

warranty

 (

excluding

 

repair

 

or

 

replacement

):

   

1

Damage

 

due

 

to

 

improper

 

use

storage

 

or

 

maintenance

 

by

 

user

   

2

Damage

 

due

 

to

 

dismantle

 

or

 

repair

 

by

 

unauthorized

 

agency

 

or

 

personnel

 

or

 

by

 

user

 

itself

   

3

The

 

warranty

 

period

 

or

 

service

 

life

 

of

 

the

 

product

 

has

 

expired

.

   

4

Damage

 

due

 

to

 

force

 

majeure

   

5

Other

 

man

-

made

 

damages

3

The

 

terminal

 

screws

 

of

 

the

 

capacitor

 

generate

 

heat

 

or

 

even

 

turn

 

into

 

black

 

during

 

operation

.

The

 

wire

 

nuts

 

are

 

loose

 

or

 

not

 

tightened

 

properly

 

during

 

installation

.

If

 

the

 

nuts

 

are

 

tightened

 

properly

the

 

reason

 

might

 

be

 

long

-

term

 

overcurrent

 

due

 

to

 

harmonic

 

current

 

amplification

 

in

 

the

 

grid

Tighten

 

the

 

nuts

replace

 

nuts

flat

 

gaskets

elastic

 

washer

 

if

 

necessary

4

The

 

fuse

 

in

 

branch

 

circuit

 

blows

 

frequently

 (

or

 

miniature

 

circuit

 

breaker

 

trips

 

frequently

); 

the

 

CJ19

 

contactor

 

fuses;

 

the

 

current

-

limiting

 

resistance

 

burns

 

frequently;

 

the

 

surface

 

of

 

XD1

 

current

-

limiting

 

reactor

 

case

 

cracks

etc

.

These

 

symptoms

 

are

 

typical

 

when

 

the

 

grid

 

harmonic

 

is

 

too

 

big

 

or

 

there

 

is

 

intermittent

 

resonance

 

in

 

the

 

grid

.

Conduct

 

grid

 

harmonic

 

test

 

or

 

check

 

if

 

there

 

are

 

harmonic

 

sources

 

such

 

as

 

frequent

 

converter

rectifier

intermediate

 

frequency

 

furnace

 

or

 

electric

-

arc

 

furnace

 

installed

 

at

 

load

 

end

See

 

3

.

3

.

2

 

for

 

harmonic

 

suppression

 

measures

.

5

Sometimes

 

there

 

is

 

buzzing

 

sound

 

in

 

the

 

cabinet

 

during

 

operation

There

 

is

 

harmonic

 

current

 

passing

 

through

 

the

 

capacitor

.

User

 

must

 

take

 

harmonic

 

suppression

 

measures

 

if

 

the

 

harmonic

 

current

 

is

 

too

 

big

 (

same

 

as

 

4

)

6

There

 

is

 

significant

 

current

 

increase

 

when

 

adding

 

a

 

capacitor

 

into

 

a

 

group

.

Either

 

abnormal

 

power

 

frequency

 

resonance

 (

underloading

), 

or

 

harmonic

 

current

 

amplification

 

or

 

there

 

is

 

resonance

.

Same

 

as

 

4

7

Slight

 

deformation

 

occurs

 

to

 

the

 

capacitor

 

case

 

after

 

the

 

capacitor

 

has

 

been

 

used

 

for

 

a

 

period

 

of

 

time

and

 

no

 

current

 

can

 

be

 

detected

Long

-

term

 

overtemperature

 

or

 

overcurrent

 

operation

 

of

 

the

 

capacitor

 

which

 

cause

 

self

-

healing

 

breakdown

 

of

 

internal

 

components

 

that

 

generates

 

gases

 

and

 

increases

 

internal

 

pressure

When

 

the

 

overpressure

 

protector

 

breaks

slight

 

deformation

 

can

 

occur

 

to

 

the

 

capacitor

 

case

.

Use

 

heat

 

dissipation

 

measures

 

to

 

lower

 

the

 

ambient

 

operating

 

temperature

 

of

 

the

 

capacitor

Select

 

products

 

with

 

higher

 

rated

 

voltage

Harmonic

 

suppression

 

measures

 

are

 

the

 

same

 

as

 

described

 

in

 

4

.

No

.

Faults

Cause

 

analysis

Troubleshooting

 

method

Environmental

 

Protection

 

and

 

Warranty

 

Period

BZMJ Series Self-healing Low Voltage Shunt Capacitors

Summary of Contents for BZMJ Series

Page 1: ...BZMJ Series Self healing Low Voltage Shunt Capacitors Standard IEC 60931 1 2014 IEC 60831 2 2014 NO 2021 01 ...

Page 2: ...maintenance 2 Installation in any damp condensed phase environment with inflammable and explosive gas is forbidden 3 When the product is being installed or maintained the power must be switched off 4 You are prohibited from touching the conductive part when the product is operating ...

Page 3: ...Technical Parameters and Performance Installation Commissioning and Operation Main Features Outline and Installation Dimensions Analysis and Troubleshooting of Faults Maintenance and Storage Product Selection and Ordering Information Environmental Protection and Warranty Period 11 Environmental Protection 01 01 01 02 04 04 06 06 07 08 08 ...

Page 4: ...Environmental conditions See Table 2 for ambient air temperature relative temperature and altitude 3 2 Installation conditions On condition that the safety precautions are met the installation site should be free from hazardous gases and vapors conductive or explosive dusts and strong mechanical vibration 3 3 Application conditions 3 3 1 The rated voltage of the capacitor must be higher than the v...

Page 5: ...30 1 4 120 Figure 1 5 140 Figure 1 6 8 190 Figure 1 10 195 Figure 2 12 220 Figure 2 14 16 250 Figure 2 18 20 295 Figure 2 25 250 Figure 3 30 315 Figure 3 Qc 3UN Qc UN 3 3 4 See 6 2 for product installation spacing We suggest double the installation spacing if the product is installed above an altitude of 2000 meters User should take effective measures to ensure good ventilation and heat dissipatio...

Page 6: ...iniature circuit breaker is not recommended RT36 or NT00 Rated voltage UN kV Rated voltage UN kV Optimal capacity Qc kvar Optimal capacity Qc kvar Rated current IN A Rated current IN A Outline and installation dimensions Outline and installation dimensions 3 three phase 1 single phase Capacity range Capacity range Height H Height H Figure number Figure number 0 4 0 45 0 48 1 3 4 5 6 7 5 8 10 12 14...

Page 7: ...ne and installation dimensions of small square products Figure 3 Outline and installation dimensions of large square products Main Features Outline and Installation Dimensions Installation Commissioning and Operation 6 1 Assembly and fixing of mounting feet Figure 4 Installation drawings of mounting feet Insert the plastic mounting feet from the bottom of the case and fixed it onto the mounting pl...

Page 8: ... the capacitor is reliably grounded 6 5 Monitoring and recording during operation 6 5 1 User should check the operating status of the capacitors on a regular basis check if the 3 phase current is balanced by using the amperemeter in the cabinet 6 5 2 If the 3 phase current is not balanced use clamp on amperemeter to test the current and voltage of phase A phase B and phase C of each group of capac...

Page 9: ...act Remove dust and greasy dirt User should pay close attention to the cabinet and replace any damaged capacitor in time if any under compensation of power factor occurs due to significant capacitance drop 50 current decrease otherwise it may lead to penalty If all the capacitors are operating and in good condition but the power factor still cannot meet requirement user must add capacity in time t...

Page 10: ...r trips frequently the CJ19 contactor fuses the current limiting resistance burns frequently the surface of XD1 current limiting reactor case cracks etc These symptoms are typical when the grid harmonic is too big or there is intermittent resonance in the grid Conduct grid harmonic test or check if there are harmonic sources such as frequent converter rectifier intermediate frequency furnace or el...

Page 11: ...c environment and application industry Product Selection and Ordering Information Environmental Protection In order to protect the environment the product or product parts should be disposed of according to the industrial waste treatment process or be sent to the recycling station for assortment dismantling and recycling according to local regulations BZMJ Series Self healing Low Voltage Shunt Cap...

Page 12: ...09 DR J03 BZMJ Series Self healing Low Voltage Shunt Capacitors IEC 60831 1 2014 IEC 60831 2 2014 BZMJ Series Self healing Low Voltage Shunt Capacitors ...

Page 13: ...10 BZMJ Series Self healing Low Voltage Shunt Capacitors ...

Page 14: ...BZMJ Series Self healing Low Voltage Shunt Capacitors ...

Reviews: