Installation panel
1
55
.5
30
3
3
79
202.5
232.5
1
6
48
405
27
3
362
Right & outer
side of breaker
20
NA1-3200
x
/NA1-3200
x
N Drawout-type, horizontal, rear connection
NA1-3200
x
/NA1-3200
x
N Fixed-type
10
97
175
391
11
2
a
1
0
7
.5
528(4P)
413(3P)
232.5
352
465(3P)
580(4P)
3
7
70
42
.5
2
5
8
4
3
9
115
1
0
4
100
N pole
4
0
50
2
0
125
125
16×Φ13
92.5
In A
~
2000 2500
3200
a mm
20
30
C
45(Disconnected position)
2×11×17
44
0
(4
P)
3
2
5(3P)
70
Φ14
175
33
Φ11
Right & outer side of breaker
2
1
2
58
13
493(4P)
378(3P)
352
515(4P)
400(3P)
11
11
290
389
150
a
a
1
12
5
5
6
0
115
402
4×Φ12
515(4P)
400(3P)
1
50
362
2
69
28
.5
3
1
1
405
2
50
18min
211
69.5
Zero arcing covering
ferreous material
Opening hole on panel
Installation panel
Installation hole on
Right & outer side of breaker
Installation hole
on Right & outer
side of breaker
In A
2000~2500
3200
a mm
20
30
115
40
86
4
0
15
1
15
32
13
×Φ
N pole
115
115
7
2
115
40
86
N pole
15
16
13
×Φ
40
115
115
96
32
115
115
115
86
N pole
18
.5
12
13
×Φ
50
96
horizontal connection(Default Configuration)
L type vertical connection
horizontal connection shorten busbar
8×Φ4
202.5
D
C
C
C
D
C
9
4
Opening hole on panel
Installation panel
15
5.5
30
3
37
9
202.5
232.5
1
6
48
405
2
73
362
Right & outer
side of breaker
2
0
Installation panel
15
5
.5
30
3
3
79
202.5
232.5
1
6
48
405
2
73
362
Right & outer
side of breaker
2
0
NA1-3200
x
/NA1-3200
x
N Drawout-type,
vertical
, rear connection
NA1-3200
x
/NA1-3200
x
N Drawout-type
In A
~
2000 2500
3200
a mm
20
30
10
97
175
391
20
40
94
8×Φ13
1
2
6
1
0
0
50
10
0
528(4P)
413(3P)
232.5
352
465(3P)
580(4P)
37
70
4
2
.5
25
8
4
3
9
2×11×17
4
4
0(4
P)
3
2
5(3
P)
70
Φ14
175
33
Φ11
a
115
N pole
115
115
102.5
45(Disconnected position)
C
Right & outer side of breaker
Opening hole on panel
In A
2000~2500
3200
a mm
20
30
2×11×17
4
4
0
(4P)
3
2
5
(3P)
7
0
Φ14
175
33
Φ11
528(4P)
413(3P)
580(4P)
465(3P)
352
11
2
92
2
3
97
175
391
536
37
42
.5
7
0
2
5
8
43
9
10
232.5
45(Disconnected position)
Right & outer side of breaker
Opening hole on panel
horizontal connection(Default Configuration)
L type vertical connection
horizontal connection shorten busbar
32
13
×Φ
120
125
125
40
100
4
0
17
1
1
5
1
0
0
120
125
125
50
100
N Pole
2
5
16
13
×Φ
50
115
125
125
92.5
3
0
.5
1
4
25
100
75
16
13
×Φ
92.5
N Pole
a
a
C
C
C
D
C
D
1
0
4
15
Right & outer side of
insulation panel
Right & outer side of
breaker
15
Right & outer side of
insulation panel
Right & outer side of
breaker
15
Right & outer side of
insulation panel
Right & outer side of
breaker
15
Right & outer side of
insulation panel
Right & outer side of
breaker
C
NA1
Air Circuit Breaker
P-052
P-051
NA1
Air Circuit Breaker
11
4
×Φ
11
4
×Φ
11
4
×Φ
Summary of Contents for NA1
Page 1: ...Air Circuit Breaker Leading every step reliable new height ...
Page 2: ...Air Circuit Breaker Leading every step reliable new height ...
Page 3: ......
Page 4: ...Page P 001 Page P 039 ACB Air Circuit Breaker NA8G NA1 ...
Page 45: ...P 041 NA1 Air Circuit Breaker 1 3 4 5 7 8 11 12 13 14 15 ...