10. A S curve
11. Temperature compensation correction
Standard
IEC/EN60947-2
40℃
45℃
50℃
55℃
60℃
65℃
Ambient
temperature
630
630
630
630
610
610
800
800
800
800
800
800
1000
1000
1000
1000
1000
1000
1250
1250
1250
1250
1250
1250
1600
1600
1600
1500
1300
1300
2000
2000
2000
1900
1800
1650
2000
2000
2000
2000
2000
2000
NA1-1000X
200
200
200
200
200
192
400
395
384
328
248
192
630
623
605
584
548
500
800
800
800
800
800
800
1000
985
960
924
870
810
NA1-3200X/NA1-3200XN
NA1-4000X
2500
2500
2500
2300
2200
2200
3200
3200
3200
3000
2800
2600
4000
3800
3600
3400
3200
3000
4000
4000
4000
4000
4000
4000
5000
5000
5000
4800
4800
4600
6300
6000
5600
5400
5200
5100
70℃
473
800
1000
1200
1200
1400
2000
170
170
473
750
750
2000
2200
2520
4000
4000
4200
Is: prospective symmetrical current(of an a.c. circuit)
2
2
6
I t(A s×10 )
NA1-2000X/NA1-2000XN/NA1-2000XH
NA1-6300X/
NA1-6300XN
Inm(A)
NA1-2000
X
/NA1-2000
X
N/NA1-2000
X
H
NA1-3200
X
/NA1-3200
X
N
NA1-4000
X
In(A)
630
5
60
2
800
6
60
2
1000
8
60
2
1250
10
60
2
Thickness(mm)
Width(mm)
Number
Busbar
1600
12
60
2
2000
10
60
3
2000
8
100
2
2500
10
100
2
3200
10
100
4
4000/3P
10
120
4
4000/4P
4000
10
100
5
5000
10
100
7
6300
10
100
8
Note: the specifications in the table is obtained as the ambient temperature of air circuit breaker is 40℃, with open installation; this is in
compliance with the specification of copper busbars adopted under the heating conditions regulated in IEC/EN60947-2.
8. Recommendation for user's connecting bus-bar
NA1-1000
X
200
5
30
1
400
5
30
2
630
5
40
2
800
6
50
2
1000
8
50
2
NA1-6300
X
/NA1-6300
X
N
-
-
-
Inm(A)
NA1-4000
X
NA1-6300
X
/NA1-6300
X
N
In(A)
3200
737
307
4000/3P
921
4000/4P
-
4000
575
-
5000
898
-
6300
1426
-
630
70
34.4
800
110
50
1000
172
78
1250
268
122
1600
440
200
2000
530
262
2000
384
200
2500
600
312
9. Power loss
Drawer type
Fixed type
Power
loss (W)
NA1-1000
X
200
40
33
400
101
85
630
123
107
800
110
94
1000
171
146
450
NA1-2000
X
/NA1-2000
X
N/NA1-2000
X
H
NA1-3200
X
/NA1-3200
X
N
-
Note: The ACB is to calibrated at 40℃, special application please refer to the table above and the curve below.
0
100
200
300
400
500
600
700
800
900
1000
1100
40
45
50
55
60
65
70
In
=200
A
In
=400
A
In
=630
A
In
=800
A
In
=1000
A
400
500
600
700
800
900
1000
1100
1200
1300
1400
1500
1600
1700
1800
1900
2000
40
45
50
55
60
65
70
In
=630
A
In
=800
A
In
=1000
A
In
=1250
A
In
=1600
A
In
=2000
A
1800
2000
2200
2400
2600
2800
3000
3200
3400
3600
3800
4000
4200
40
45
50
55
60
65
70
In
=2000
A
In
=2500
A
In
=3200
A
In
=4000
A
3800
4000
4200
4400
4600
4800
5000
5200
5400
5600
5800
6000
6200
6400
40
45
50
55
60
65
70
In
=4000
A
In
=5000
A
In
=6300
A
Ambient temperature(℃)
Rat
ed curr
ent
(A)
NA1-6300
X
/NA1-6300
X
N
Ambient temperature(℃)
Rat
ed c
urr
ent (A)
NA1-2000
X
/NA1-2000
X
N/NA1-2000
X
H
Rat
ed curr
ent
(A)
Ambient temperature(℃)
NA1-3200
X
/NA1-3200
X
N/NA1-4000
X
Ambient temperature(℃)
NA1-1000
X
Rat
ed c
urr
ent (A)
Summary of Contents for NA1
Page 1: ...Air Circuit Breaker Leading every step reliable new height ...
Page 2: ...Air Circuit Breaker Leading every step reliable new height ...
Page 3: ......
Page 4: ...Page P 001 Page P 039 ACB Air Circuit Breaker NA8G NA1 ...
Page 45: ...P 041 NA1 Air Circuit Breaker 1 3 4 5 7 8 11 12 13 14 15 ...