14.0. PREVENTATIVE MAINTENANCE (Cont.):
14.3. OIL CHANGE PROCEDURE:
IT IS EXTREMELY IMPORTANT TO DISCONNECT AND LOCKOUT
ANY AND ALL POWER SOURCES BEFORE ANY WORK IS TO BE
PERFORMED ON the ChipBLASTER UNIT.
14.3.1. ChipBLASTER High-Pressure Pump: Change the crankcase oil after every 2000 hours
of operation.
USE:
Mobil 1 fully synthetic 15W-50 oil.
14.3.2. Remove accesses panel from right side, as viewed from enclosure end, (use 4mm
hex head wrench).
14.3.3. Locate and remove the oil fill cap/dipstick located on top of pump.
14.3.4. Locate and remove the drain plug (use 17mm wrench) located on back side of
pump (opposite the head end). Allow oil to drain into a container capable of
holding at least 1 liter (32 ounces).
FAILURE TO USE
MOBIL 1 FULLY-SYNTHETIC 15W-50 OIL
WILL VOID YOUR WARRANTY
!
FILL-CAP/
DIPSTICK
14.3
DRAIN PLUG
DRAIN OIL
CONTAINER