ChipBLASTER Inc
41
19.0. SYSTEM CONTAMINATION PURGING PROCEDURE:
19.1. Tools Required:
19.1.1.
4mm Hex Head Wrench
19.1.2.
3/8” Hex Head Wrench
19.1.3.
5 Gallon Fluid Container
19.1.4.
Section of Low Pressure Hose
19.1.5.
Adapter Fitting (½” NPT to Hose Connection)
19.2. Change Filter Cartridge: SEE SECTION 14.14
IF THERE IS PRESSURE PRESENT DO NOT OPEN FILTER HOUSING
SEEK ASSISTANCE FROM QUALIFIED MAINTENANCE
PERSONNEL TO RELIEVE PRESSURE.
19.3 Install
Purge
Hose:
19.3.1.
Remove right side access panel from ChipBLASTER unit using 4mm hex head
wrench (Panel on right side as viewed from enclosure end).
19.3.2.
Locate & remove ½” NPT plug from end of manifold block using 3/8” hex head
wrench.
19.3.3. Install ½” NPT to hose adapter fitting in the end port and attach low-pressure
hose.
!
19.0
½” NPT
PLUG
REGULATOR
MANIFOLD
BLOCK