Section 3: Operation
Mirage S+/HD, Matrix S+/HD, Christie HD/DS+/DW, DLV User Manual
3-49
020-100001-05 Rev. 1 (12-2008)
projector’s display area.
3)
Adjust white levels before adjusting black levels.
4)
Blinders are recommended for fixed installations.
Default Color Adjustments
— SUBMENU
Refer to
System Configuration – Geometry and Color, Color Adjustments by X,Y
for
description.
Intelligent Lens System (ILS
™
)
— SUBMENU
ILS
™
provides the ability to recall focus and zoom settings specific to each source
input. Custom lens settings you’ve chosen for any source will be quickly and
accurately applied when you select a source that has already been calibrated. Place a
checkmark in the checkbox to enable ILS
™
. If no calibration has previously been
done you may be prompted to do a full calibration. If a motion calibration has been
done, you will be prompted to complete a reference calibration. If both calibrations
have been done, the checkbox will be checked and ILS
™
enabled. If ILS
™
is enabled,
a reference calibration will be done on power up and the lens will return to the saved
position of the source that is active at the time of power up or to the position the lens
was located when it was powered on. Further adjustments to the zoom, focus and
position will be automatically saved for source the selected source. If you switch to a
source with different lens settings and switch back, the lens will automatically move
to your saved settings upon return. Other sources can be used without using ILS
™
.
NOTES:
1)
See
System Configuration – Diagnostics/Calibration, ILS Calibration
for further details about calibration.
2)
ILS
™
control is a preference setting and will
be retained between power cycles.
Test Pattern
Choose the desired internal test pattern to
display, or select OFF to turn off a test
pattern. Alternatively, use the
Test
key
for cycling through test patterns.
NOTE:
There is a centerline (both
horizontal and vertical) in the Edge
Blending test pattern. The intersection of
these lines is the true center of the
projector’s display area.
Test Pattern Grey Level
Set the desired level of grey for displaying in the full gray field test pattern.
Freeze Image
Enter a check mark to freeze (stop) an image on a single frame. This diagnostic tool is
useful if you need to examine in detail a still version of an incoming image that cannot
be “frozen” at the source. For example, in moving images it is sometimes difficult to
observe artifacts such as external de-interlacing/resizing and signal noise. Remove the
checkmark to return back to normal.
System
Configuration
DIAGNOSTICS / CALIBRATION
1.
2.
3.
4.
5.
7.
8.
9.
0.
6.
Test Pattern
Grey Level
Freeze Image
Color Enable
Odd Pixel Adjustment
Peak Detector
Level Detector
Level Value
Aspect Ratio Overlay
LiteLOC Calibration
ILS Calibration
Automatic ILS Lens Calibration
Reserved
Diagnostics and Calibration
Grid
512
White
512
Calibrate LiteLOC
Full Calibration