Safety attention operation
Please read carefully before operating the air compressor:
1.
The ground must be flat and strong in the position of the air compressor, and there should be no
flammable smoke or steam around it, such as thinners for paint, otherwise there will be a fire or
explosion;
2.
Installation of pipe welding, should pay attention to prevent welding sparks fall into the air
compressor or splashing into the air compressor cover, avoid burning down some parts of the air
compressor;
3.
The power supply line leading to the air compressor must match its power and install the air
switch, fuse wire and other safety devices. In order to ensure the reliable safety of electrical
equipment, there must be grounding device;
4.
A very short time before starting the compressor (about 1 second), check the direction of rotation,
must ensure that the direction of rotation of the air compressor is correct, otherwise a few seconds
may cause damage to the compressor air end;
5.
The air compressor shall confirm that the power supply has been cut off and the system is not
under pressure when it is overhauled or maintained, and shall mark the warning signs such as
"overhaul" or "no closing" at the power supply;
6.
When the unit is in operation, do not loose, remove any pipe accessories, joints and devices. The
unit is filled with high pressure and high temperature liquid and gas, which can cause serious
personal injury accident.
7.
The compressor cannot work under the exhaust pressure specified by the nameplate, otherwise
the motor will be overloaded, resulting in the motor and compressor stopping;
8.
Before carrying out maintenance (such as re-inject new oil) and maintenance work on the
compressor, it is necessary to:
1) Stopping the unit;
2) Cutting off the power supply to ensure that the compressor is out of power;
3) Ensure that the compressor system is free of pressure.
9.
The relief valve is installed on the oil separator seat. Once the gas pressure in the system exceeds
the set pressure, the gas will be released through the valve. Check the cause of over-pressure at this
time;
10.
After the air compressor runs for a certain time, the safety valve, temperature sensor, pressure
sensor and other protection systems should be inspected regularly to ensure its sensitivity and
reliability. It is generally inspected once a year;
11.
Must use our company designated recommended screw air compressor special oil, prohibit
mixed use of different grades of lubricating oil.
Summary of Contents for Quan Wei
Page 1: ...TaiWan QuanWei Screw type air compressor Using and Maintenance Instructions ...
Page 12: ...8 ...
Page 81: ...77 ...
Page 82: ...78 8 2 2 QWL 15A 20A 8 2 3 QWL 30A 40A ...
Page 83: ...79 8 2 4 QWL 50A 60A ...
Page 84: ...80 8 2 5 QWL 75A 100A ...
Page 85: ...81 8 2 6 QWL 150A 175A ...
Page 86: ...82 9 0 Circuit diagram ...
Page 87: ...83 9 1 MAM 860 880 Circuit diagram 9 2 MAM 890 Circuit diagram ...
Page 88: ...84 9 3 MAM 6080 Circuit diagram ...
Page 89: ...85 Screw Air Compressor operation record tale ...