32
Dormant backlight
brightness
0000
Used to set the brightness of the backlight when the
controller is un-operated for a long time.
5.1.6
Factory parameters
The factory parameters are used to store the relevant data set by the air compressor
manufacturer, the user can view or modify the factory parameters, and the password of the
manufacturer should be verified. The factory parameter modification operation method is the
same as the user parameter modification method.
The main functions and functions are shown in the table below:
Menu
Set
initial
value
Function description
Motor rated electricity
(
A
):
Maximum
allowable
overload of
motor
value
/1.2
The current of the
motor is more than 1.2 times of the set
value.
Fan motor rated
electricity
(
A
):
Maximum
allowable
overload of
wind motor
value
/1.2
The current of wind motor is more than 1.2 times of the set value.
Exhaust warning
temperature
(℃):
0105
Warning if exhaust temperature is higher than this set temperature.
Exhaust stop
temperature
(℃):
0110
Failure stop when exhaust temperature is higher than this set
temperature.
Front bearing warning
temperature
(℃):
0105
When the temperature of the front bearing is higher than this set
temperature, early warning (reserve).
Front bearing stop
temperature
(℃):
0110
Failure shutdown when front bearing temperature is higher than
this set temperature (standby).
Air supply shutdown
pressure
(
MPa
):
00.90
When the gas supply pressure is higher than this set pressure,
the fault stops.
System shutdown
pressure
(
MPa)
:
01.00
Failure shutdown when system pressure is higher than this set
pressure.
Unloading pressure high
limit
(
MPa)
:
00.85
This is the maximum "unload pressure" in the user parameter,
and the unloading pressure
≤
set here.
Summary of Contents for Quan Wei
Page 1: ...TaiWan QuanWei Screw type air compressor Using and Maintenance Instructions ...
Page 12: ...8 ...
Page 81: ...77 ...
Page 82: ...78 8 2 2 QWL 15A 20A 8 2 3 QWL 30A 40A ...
Page 83: ...79 8 2 4 QWL 50A 60A ...
Page 84: ...80 8 2 5 QWL 75A 100A ...
Page 85: ...81 8 2 6 QWL 150A 175A ...
Page 86: ...82 9 0 Circuit diagram ...
Page 87: ...83 9 1 MAM 860 880 Circuit diagram 9 2 MAM 890 Circuit diagram ...
Page 88: ...84 9 3 MAM 6080 Circuit diagram ...
Page 89: ...85 Screw Air Compressor operation record tale ...