41
Operating state=
Operating
word
AND
0001=0001
Used to determine whether the frequency converter has run the
formula. For details, please refer to the frequency converter
manual, communication section.
Date format
:
8N1-N
Set the data format when the controller communicates with the
frequency converter.
This setting should be consistent with the frequency converter
communication format setting.
8N1-N: one start bit, eight data bits, one stop bit, no check bit;
8N1-E: one start bit, eight data bits, one stop bit, even checkbit;
8N1-O: one start bit, eight data bits, one stop bit, odd check bit;
8N2-N: one start bit, eight data bits, two stop bits, no check bits;
Note: in communication with frequency converter, baud rateis
fixed at: 9600.
Frequency address
0C82
Reading Frequency converter frequency address.(refer to
Frequency converter manual)
Frequency
Display=
receive*000
1
÷
0001
The frequency formula of frequency converter is calculated.
The controller converts the read frequency to 1 decimal place
data.
Voltage address
0C88
Read Frequency converter voltage address.
Voltage Display=
receive*000
1
÷
0001
Calculate the voltage formula of frequency converter.
The controller converts the read voltage to 1 decimal place data.
Electricity address
0C84
Read Frequency converter electricity address.
Electricity
Display=
receive*000
1
÷
0001
The formula of frequency converter current is calculated.
The controller converts the read current into 1 decimal place data.
Power address
0C8B
Read Frequency converter Power address.
Power=
receive*1*0
01
÷
0001
Calculate Frequency converter Power formula.
Malfunction
address
8000
Read Frequency converter malfunction location.
Malfunction state=
Malfunction
receive
value AND
0000
≠
0000
Whether frequency converter reports failure formula.
Emergency stop
address
2135
The address of the Frequency converter stop order.
Send date
0001
This setting value is the starting value of frequency converter.
For different frequency converters, please refer to the frequency
converter manual and communication section.
5.1.12
Screen calibration
Screen calibration is used to calibrate screen operation accuracy. The user needs to verify the
screen calibration password before entering the screen calibration. When you enter the screen
Summary of Contents for Quan Wei
Page 1: ...TaiWan QuanWei Screw type air compressor Using and Maintenance Instructions ...
Page 12: ...8 ...
Page 81: ...77 ...
Page 82: ...78 8 2 2 QWL 15A 20A 8 2 3 QWL 30A 40A ...
Page 83: ...79 8 2 4 QWL 50A 60A ...
Page 84: ...80 8 2 5 QWL 75A 100A ...
Page 85: ...81 8 2 6 QWL 150A 175A ...
Page 86: ...82 9 0 Circuit diagram ...
Page 87: ...83 9 1 MAM 860 880 Circuit diagram 9 2 MAM 890 Circuit diagram ...
Page 88: ...84 9 3 MAM 6080 Circuit diagram ...
Page 89: ...85 Screw Air Compressor operation record tale ...