46
Communication stop
Frequency converter
times
06
After the controller sends the stop command to the frequency
converter, it is found that the frequency converter does not
execute the stop command, and the
stop command is sent repeatedly at most.
Variable Frequency
main motor
Electricity
consumption
(Kw.H)
0000000.0
Setting up the accumulative power consumption of the mainframe
Variable Frequency operation.
Preset main motor
Frequency converter
delay time(S)
001.0
Pressstartkey, delaysettingtime,sendtheswitch
on command
Integral gain2
0000
The tracking sets the working pressure fast and slowlyand
determinesthesteady-stateerror,thevalue big tracking fast, the
steady-state error small, the value small tracking slowly, the
steady-state error
big.
Integral gain2
range
(MPa)
00.00
Set the integral gain 2 range.
ConstantPowerpressur
e1(MPa)
0.60
For constant power operation, when the detection pressureis
greaterthanorequaltothesetvaluehere, theoutputfrequencyis
allowedtobea"constantpower
frequency 1" setting value at most.
ConstantPowerpressur
e2(MPa)
0.70
For constant power operation, when the detection pressureis
greaterthanorequaltothesetvaluehere, theoutputfrequencyis
allowedtobea"constantpower
frequency 2" setting value at most.
ConstantPowerpressur
e3(MPa)
0.80
For constant power operation, when the detection pressure is
greater than or equal to the set value here, the output frequency
is allowed to be a "constant power frequency 3" setting value at
most.
ConstantPowerpressur
e4(MPa)
0.90
For constant power operation, when the detection pressure is
greater than or equal to the set value here, the output frequency
is allowed to be a "constant power frequency 4" setting value at
most.
ConstantPowerpressur
e5(MPa)
1.00
For constant power operation, when the detection pressure is
greater than or equal to the set value here, the output frequency
is allowed to be a "constant power frequency5" setting value at
most.
ConstantPowerpressur
e6(MPa)
1.10
For constant power operation, when the detection pressure is
greater than or equal to the set value here, the output frequency
is allowed to be a "constant power frequency 6" setting value at
most.
Summary of Contents for Quan Wei
Page 1: ...TaiWan QuanWei Screw type air compressor Using and Maintenance Instructions ...
Page 12: ...8 ...
Page 81: ...77 ...
Page 82: ...78 8 2 2 QWL 15A 20A 8 2 3 QWL 30A 40A ...
Page 83: ...79 8 2 4 QWL 50A 60A ...
Page 84: ...80 8 2 5 QWL 75A 100A ...
Page 85: ...81 8 2 6 QWL 150A 175A ...
Page 86: ...82 9 0 Circuit diagram ...
Page 87: ...83 9 1 MAM 860 880 Circuit diagram 9 2 MAM 890 Circuit diagram ...
Page 88: ...84 9 3 MAM 6080 Circuit diagram ...
Page 89: ...85 Screw Air Compressor operation record tale ...