49
Fan motor constant
RPM(RPM)
1500
When the maximum frequency of the wind motor is set, the actual
speed of the motor is calculated when it is used in the Variable
Frequency operation of the motor. (This parameter only works when
the model is set to be variable frequency of wind motor or Variable
Frequency
of fan motor).
Variable Frequency Fan
motor start
(℃)
0070
Whentheexhausttemperatureisgreaterthanthisset value, the
Variable Frequency fan starts. (This parameter only works when
the model is set to be
variable frequency of the wind motor, or the fan motor
is variable frequency.).
Variable Frequency Fan
motor stop
(℃)
0065
When the exhaust temperature is lower than this set value,the
Frequencyconverterwindmotorstops.(This
parameter only works when the model is set to be variable
frequencyofwindmotororVariableFrequency
of fan motor).
Fan motor Integral initial
value
0020
When the detection temperature is < (setting the Variable
Frequency working temperature-integral
range), the integral is calculated with this set value; When the
detection temperature is > (setting Variable Frequency working
tempe integral range), the
integral is calculated with this set value.
Fan motor Integral range
(℃)
0005
(set Variable Frequency working temperature-integral range)
< Detection temperature < (set Variable Frequency working
tempe integral range) integral gain function. Outside this
range, the initial value of the integral works.
Fan motor Proportional
gain
0100
Track setting working temperature fast, value large tracking
fast, easy to oscillate; value small tracking slow, slow
adjustment.
Fan motor Integral gain
0020
The tracking setting temperature is fast and slow and the
steady-state error is determined, the value big tracking fast
steady state error is small, the value small tracking is slow, the
steady state error is big.
Fan motor Differential
gain
0000
Generally not, set to "0000".
Fan motor frequency
Upper limit
(
HZ)
050.0
During adjustment, the maximum operating frequency of the
output is allowed when the temperature exceeds the Variable
Frequency operating temperature.
Fan motor frequency
Lower limit
(
HZ)
010.0
During adjustment, the minimum operating frequency of the
output is allowed when the temperature is lower than the
operating temperature of the Variable Frequency.
Variable Frequency Fan
motor Power Coefficient
0.
9
00
Calculation of Power coefficient of variable Frequency Wind
Motor.
Summary of Contents for Quan Wei
Page 1: ...TaiWan QuanWei Screw type air compressor Using and Maintenance Instructions ...
Page 12: ...8 ...
Page 81: ...77 ...
Page 82: ...78 8 2 2 QWL 15A 20A 8 2 3 QWL 30A 40A ...
Page 83: ...79 8 2 4 QWL 50A 60A ...
Page 84: ...80 8 2 5 QWL 75A 100A ...
Page 85: ...81 8 2 6 QWL 150A 175A ...
Page 86: ...82 9 0 Circuit diagram ...
Page 87: ...83 9 1 MAM 860 880 Circuit diagram 9 2 MAM 890 Circuit diagram ...
Page 88: ...84 9 3 MAM 6080 Circuit diagram ...
Page 89: ...85 Screw Air Compressor operation record tale ...