QuanWei MACHINERY (Jiang Su)
62
parameters.
The adjustment parameter modification operation method is the same as the user parameter
modification method.
The main functions and functions are shown in the table below
:
Motor
A
phase
Standard
electricity
0000
1. It is used to calibrate the A phase currentof the motor. After the
standard current value is input, the controller automatically calculates
the current coefficient and saves it to complete the currentcalibration.
2. After the calibration is completed, the standard current value is
automatically returned to zero.
Coefficient
1.000
When calibrating the current, the input coefficient.
Controller display current value = sampling value
×
coefficient
Current
electricity
***.*A
Current real-time electricity value
Motor
B
phase
Standard
electricity
0000
1. It is used to calibrate the B phase current of the motor. After the
standard current value is input, the controller automatically calculates
the current coefficient and saves it to complete the currentcalibration.
2. After the calibration is completed, the standard current value is
automatically returned to zero.
Coefficient
1.000
When calibrating the current, the input coefficient. Controller
display current value = sampling value
×
coefficient
Current
electricity
***.*A
Current real-time electricity value
Motor
C
phase
Standard
electricity
0000
1. It is used to calibrate the C phase current of the motor. After the
standard current value is input, the controller automatically calculates
the current coefficient and saves it to complete the currentcalibration.
2. After the calibration is completed, the standard current value is
automatically returned to zero.
Coefficient
1.000
When calibrating the current, the input coefficient.
Controller display current value = sampling value
×
coefficient.
Current
electricity
***.*A
Current real-time electricity value.
Fan motor
A
phase
Standard
electricity
0000
1. It is used to calibrate the A phase current of wind motor. After
input standard current value, the controller automatically calculatesthe
current coefficient and saves it to complete the current calibration.
2. After the calibration is completed, the standard current value is
automatically returned to zero.
Coefficient
1.000
When calibrating the current, the input coefficient.
Controller display current value = sampling value
×
coefficient
Current
electricity
***.*A
Current real-time electricity value
Fan motor
Standard
0000
1. It is used to calibrate the B phase current of wind motor. After
Summary of Contents for Quan Wei
Page 1: ...TaiWan QuanWei Screw type air compressor Using and Maintenance Instructions ...
Page 12: ...8 ...
Page 81: ...77 ...
Page 82: ...78 8 2 2 QWL 15A 20A 8 2 3 QWL 30A 40A ...
Page 83: ...79 8 2 4 QWL 50A 60A ...
Page 84: ...80 8 2 5 QWL 75A 100A ...
Page 85: ...81 8 2 6 QWL 150A 175A ...
Page 86: ...82 9 0 Circuit diagram ...
Page 87: ...83 9 1 MAM 860 880 Circuit diagram 9 2 MAM 890 Circuit diagram ...
Page 88: ...84 9 3 MAM 6080 Circuit diagram ...
Page 89: ...85 Screw Air Compressor operation record tale ...