background image

 

30 
 

 

Management 

1

Device Administration Setting 

Summary of Contents for BF-1010

Page 1: ...BF 1010 User Manual Document Version 2 0 Web Version 1 8 Jan 15 2018 Firmware Version 1 11 09 Oct 3 2019 ...

Page 2: ...8 2 DHCP CLIENT 9 Function Description 9 3 PPPoE 10 Function Description 10 Network operation mode 11 Data PORT 1 11 1 TCP Server 11 Function Description 12 2 TCP Client 13 Function Description 13 3 UDP Client 14 Function Description 14 Data PORT 2 15 1 TCP Server 15 Function Description 15 2 TCP Client 16 Function Description 16 3 UDP Client 17 Function Description 17 I O PORT 18 1 TCP Server 18 ...

Page 3: ...up 28 Function Description 28 System Log 29 Function Description 29 Management 30 1 Device Administration Setting 30 Function Description 31 2 System Status Monitor 32 Function Description 33 3 I O Status 34 Function Description 34 4 Backup Restore Configuration 35 Function Description 35 5 Firmware Upgrade 36 Function Description 36 6 PING 37 Function Description 37 Copyright 2011 All Rights Rese...

Page 4: ...n 2 500V DC 4 Built in relay made in Japan DC30V 1A Web interface 1 1 RJ 45 ports 2 10 100Base T full half duplex support 3 Automatic jumper detection RS 485 interface 1 2 groups of RS 485 2 Connect with terminal block LED display 1 Power status light 2 Network status light 3 2 groups of RS 485 status lights 4 10 groups of digital input status status lights 5 10 sets of digital output status light...

Page 5: ...2 Endpoint description ...

Page 6: ... server Support PPPoE function PPPoE is a protocol to establish a connection with the remote host through the DSL connection analog dial up connection to the Internet Support dynamic DNS function which allows BF 1010 to connect with dynamic wide area IP with a fixed name Domain Name making it easier for hosts in different locations to access BF 1010 through the Internet Automatically detect 10 100...

Page 7: ...nstalled and powered on If the default IP address 192 168 0 125 of BF 1010 has been adopted by other devices you should turn off the other devices until the setting is completed and assign a new IP address to BF 1010 How to search BF 1010 1 After installing BF 1010 and confirming that the network cable has been installed use BF 1010 to search the IP address IP Search can find all the BF 1010 in th...

Page 8: ...information of the selected BF 1010 will be displayed at the bottom of the window as shown below 4 The BF 1010 information displayed at the bottom of the window can be directly modified to the BF 1010 The parts that can be modified are IP Address Subnet Mask Gateway Software IP Software Port Terminal ID After modifying the required information MAC Address cannot be modified after clicking Alter th...

Page 9: ... time there are the following two methods 1 After starting IP Search select the BF 1010 to be entered and then double click to enter the selected BF 1010 webpage 2 After opening the web browser enter the BF 1010 IP address where you want to enter the web address you can enter the BF 1010 web page Remark WINDOWS XP Step 1 Click WINDOWS XP My PC to open and select the left Control panel Please switc...

Page 10: ...r the IP address of the computer does not match the IP address of BF 1010 Set the computer IP to the IP address of the same network segment as BF 1010 If the computer uses a fixed IP address the address must be between 192 168 0 1 192 168 0 124 or 192 168 0 126 192 168 0 254 Within the range in order to be compatible with the BF 1010 s default IP address 192 168 0 66 the setting of Subnet Mask mus...

Page 11: ... Address Set the IP address of BF 1010 the default value is 192 168 0 125 Subnet mask Set the Subnet mask of BF 1010 the default value is 255 255 255 0 Gateway Set the default Gateway of BF 1010 the default value is 192 168 0 254 Primary DNS Set the DNS of BF 1010 the default value is 168 95 1 1 ...

Page 12: ...9 2 DHCP CLIENT Function Description Host Name optional Enter host name the default is BF 1010 non required field ...

Page 13: ...dle Time Over 1 Set the idle disconnection time seconds the default value is 0 seconds the range is 0 4294967295 2 If you want to keep BF 1010 and ISP connected at any time you must set this value to 0 otherwise if there is nodata transmission exceeding the set time it will automatically disconnect with PPPoE PPPoE with Fixed IP Address 1 When PPPoE uses fixed IP enter ENABLE after selecting ENABL...

Page 14: ...11 Network operation mode Data PORT 1 1 TCP Server ...

Page 15: ... the monitoring at all times you must set this value to 0 otherwise the segment connection will be automatically cut when no data is transmitted on the line beyond the set time Max Connection Set the maximum number of TCP connections the maximum can be set to 3 TCP connections the default value is 3 Access Password To ensure the security of datas the user can set a password to enter and control Wh...

Page 16: ...ion IP Address 2 Set the remote IP address and port number of the second group the range of PORT is 0 65535 the default is 50000 Destination IP Address 3 Set the remote IP address and port number of the third group the range of PORT is 0 65535 the default is 50000 Keep Alive Check When connected a ping packet is sent to the Gateway Router to ensure the connection every 30 seconds ...

Page 17: ...mber of the second group the range of PORT is 0 65535 the default value is 50000 Destination IP Address 3 Set the remote IP address and port number of the third group the range of PORT is 0 65535 the default value is 50000 Local Listen Port Set the local receiving port number the default value is 50000 the range is 0 65535 Keep Alive Check When connected a ping packet is sent to the Gateway Router...

Page 18: ...on between BF 1010 and the monitoring terminal at any time you must set the value to 0 otherwise when there is no data on the line and the transmission exceeds the set time the connection will be automatically disconnected Max Connection Set the maximum number of TCP connections up to 3 TCP connections the default value is 3 Access Password To ensure the security of assets the user can set a passw...

Page 19: ... IP Address 2 Set the remote IP address and port number of the second group the range of PORT is 0 65535 the default value is 50001 Destination IP Address 3 Set the remote IP address and port number of the third group the range of PORT is 0 65535 the default value is 50001 Keep Alive Check When connected a ping packet is sent to the Gateway Router to ensure the connection every 30 seconds ...

Page 20: ...mber of the second group the range of PORT is 0 65535 the default value is 50001 Destination IP Address 3 Set the remote IP address and port number of the third group the range of PORT is 0 65535 the default value is 50001 Local Listen Port Set the local receiving port number the default value is 50002 the range is 0 65535 Keep Alive Check When connected a ping packet is sent to the Gateway Router...

Page 21: ...e to 0 otherwise when there is no data transmission on the connection exceeding the set time it will automatically disconnect Max Connection Set the maximum number of TCP connections the maximum can be set to 3 TCP connections the default value is 3 Access Password To ensure the security of assets the user can set a password to enter and control When the assets are transferred the correct password...

Page 22: ... IP Address 2 Set the remote IP address and port number of the second group the range of PORT is 0 65535 the default value is 50002 Destination IP Address 3 Set the remote IP address and port number of the third group the range of PORT is 0 65535 the default value is 50002 Keep Alive Check When connected a ping packet is sent to the Gateway Router to ensure the connection every 30 seconds ...

Page 23: ...mber of the second group the range of PORT is 0 65535 the default value is 50002 Destination IP Address 3 Set the remote IP address and port number of the third group the range of PORT is 0 65535 the default value is 50002 Local Listen Port Set the local receiving port number the default value is 50002 the range is 0 65535 Keep Alive Check When connected a ping packet is sent to the Gateway Router...

Page 24: ...0 230400 and others 2 After selecting Others you must enter a custom baud rate in the User Defined space 3 The default value is 19200 Data Bits Set the data bit there are 5 6 7 8 can be set the default value is 8 Parity Check Set the check digit there are 4 types can be set The default is None 1 Odd 2 Even 3 Mark 4 Space Stop Bits Set the stop bit there are 1 2 can be set the default value is 1 ...

Page 25: ...ser Defined space 3 The default value is 19200 Data Bits Set the data bit there are 5 6 7 8 can be set the default value is 8 Parity Check Set the check digit there are 4 types can be set The default is None 1 Odd 2 Even 3 Mark 4 Space Stop Bits Set the stop bit there are 1 2 can be set the default value is 1 Terminal ID The range is 0 255 0 is for Master Only the default value is 1 Working Mode I...

Page 26: ...ed to normal Function Description INPUT No It can set from IN1 IN10 The drop down menu provides two states LOW and HIGH which can be selected the DEFULT is LOW OUTPUT No In the drop down menu provide None and OUT 1 OUT 10 can be selected the default is None Trigger seconds when abnormal Set the duration of OUTPUT trigger the setting range is 0 65535 seconds the default is 0 seconds Once set to 0 s...

Page 27: ...work Optix please fill the NX Server IP NX Server Port Fill the NX Server Port the default is 7001 User name It s the account number to login NX the default is admin Password It s the password to login NX the default is admin12345 NX Alarm Source It can fill the sensor name ...

Page 28: ...select Temperature Humidity or CO2 Trigger Status It can set High Low or disable the default is disable Trigger Value It can set the Trigger Value for Temperature Humidity or CO2 here VMS Alarm Source It can select the Alarm Source of Sensor The default is None ...

Page 29: ...n Description Auto Report Select to enable or disable the automatic report I O function the default value is off Interval Time Set the interval time for automatic report I O can be set from 0 to 65535 seconds the default is 0 seconds ...

Page 30: ...SMTP Mail Server Set the SMTP server Take Chunghwa Telecom as an example The SMTP server is msa hinet net which can set up to 47 characters E mail Alerts To Set the recipient s mail up to 47 characters Return Address Set the sender s mail up to 47 characters SMTP Server Requires Authentication The SMTP Server needs no authentication the default value is No User name Enter SMTP Server user account ...

Page 31: ...28 System Clock Setup Function Description There re two ways to set System Clock 1 Set the Time Server to Enable and set the Time Zone to the correct area 2 Set the Date and Time then Apply it ...

Page 32: ...cription Date Display the date when the system record occurred in the order of month day year Time Display the time when the system record occurred the order is hour minute second Description Display system recorded description ...

Page 33: ...30 Management 1 Device Administration Setting ...

Page 34: ...he default is BF 1010 Device Location Set the location name of the device host the default is blank Administrator Password User Name Enter the user name Password Change Change the password please enter the new password to replace the default value Password Confirm Confirm the new password After changing the password please enter the new password again to confirm Block Ping Request Enable or disabl...

Page 35: ...32 2 System Status Monitor ...

Page 36: ...e default is 192 168 0 125 Subnet mask Display Subnet mask of BF 1010 the default is 255 255 255 0 Default Gateway Display default gateway of BF 1010 the default is 0 0 0 0 Primary DNS Display Primary DNS of BF 1010 the default is 168 95 1 1 STATUS Display BF 1010 current network status Serial Status Port 1 Display the baud rate data bit parity bit stop bit flow control of serial serial port Port ...

Page 37: ...ature Description INPUT Status Display status of BF 1010 INPUT 1 INPUT 10 the default is LOW OUTPUT Status Display status of BF 1010 OUTPUT 1 10 the default is OPEN It can click SHORT 1 10 or OPEN 1 10 to control the OPEN or SHORT of OUTPUT ...

Page 38: ...tion Backup After execution the current system settings can be saved as a backup file and stored in the hard disk The extension of the stored file is cfg Restore Browse to select the backup file cfg and restore the system settings after running Restore ...

Page 39: ... After browsing and selecting the firmware it can upgrade the firmware after executing UPGRADE The power supply must be stable during the upgrade process otherwise it will cause irreparable errors If the firmware of the same product is upgraded to other products it will also cause serious injury ...

Page 40: ...ress Enter the IP address of the remote connection host Packet Number Set to sent the number of PING packets the range is 1 4 the default is 4 Ping Size Set the PING packet size up to 1460 Bytes the default is 60 Ping Result Sent Request Display the amount of data sent Receive Reply Display the amount of data received ...

Reviews: