- 18 -

(3)UDP

Function instruction

Function

Description

Remote Connection Port Number

Set the remote connection port number

the range is 0 ~

65535

default setting is

50000

Remote Host IP Address/Domain

Name

Set remote host IP address or domain name

default setting is

blank

Local Listen Port

Set the local listen port

default setting is

50000

Heart Beat

How many seconds to transmit a UDP heart beat to server

can be selected. It’s helpful to know the connection with

SERVER enabled.

Default setting is

Disabled

, and the maximum setting is 65535

seconds.

Summary of Contents for CYT-200SC

Page 1: ...CYT 200SC User Manual Document Version 1 0 Web Version 1 1 2011 05 14 Firmware Version 1 01 00 May 17 2011 ...

Page 2: ...P Server 13 2 TCP Client 14 3 UDP 15 PORT 2 16 1 TCP Server 16 2 TCP Client 17 3 UDP 18 2 Serial Port Setup 19 1 PORT 1 19 2 PORT 2 20 3 Dynamic DNS Setup 21 1 TZ0 21 2 Dyndns 22 Management 23 1 Device Administration Setting 23 2 System Status Monitor 24 3 Backup Restore Configuration 25 4 Firmware Upgrade 26 5 PING 27 Copyright 2011 All Rights Reserved All trademarks and trade names are the prope...

Page 3: ... TxD RxD GND RS 422 Tx Tx Rx Rx GND 1200M for the longest distance RS 485 Data Data GND 1200M for the longest distance Power Input Choose one PWR1 DC9 24V 300MA MAX 2 pin Separate terminal PWR2 DC9 24V 300MA MAX DC power to DC socket Operating Temperature 0 55 Operating Humidity 5 95 RH Storage Temperature 20 85 Surge Protection Serial port 15KV ESD Electromagnetic protection Ethernet port 1 5KV L...

Page 4: ... 2 End point ...

Page 5: ...rver TCP client UDP Real com Users can select suitable connecting way Support DHCP Client when activate this function CYT 200SC can get TCP IP default from DHCP Server when the system activates Includes IP address default getaway IP and DNS server Support PPPoE PPPoE is an internet protocol for the link simulation of dial up connection and remote host Support Dynamic DNS this enable CYT 200SC conn...

Page 6: ...with power supplied If the default IP address 192 168 168 125 is occupied by else device then it is a must to shut down that device first till the setting is over and then allocate new IP address to CYT 200SC How to search CYT 200SC 1 After installation of CYT 200SC and network cable is completed use CYT 200SC s IP Search to search all CYT 200SC in a certain LAN or download IP Search tool from CHI...

Page 7: ... Address Select particular CYT 200SC then its related information will appear below the window as shown 4 The showed information of CYT 200SC can be revised directly in the window the part can be modified IP Address Subnet Mask Gateway After modification completed MAC Address can not modify click Alter then it will display the modified information as shown ...

Page 8: ...C has two methods 1 Open IP Search select and double click particular CTY 200SC then to enter its webpage 2 While the internet explorer opened input CYT 200SC IP address to enter its webpage Remark WINDOWS XP Step 1 Click WINDOWS XP my computer Open Control Pan on the left side please turn to traditional overview and select network link Step 2 Click LAN then select content the link configuration w...

Page 9: ... select open and search for click Alter Interface Card on the upper left side Step 2 Click LAN link select content then the LAN settings will be shown click Internet Protocol TCP IPv4 click and input same setting as CYT 200SC as below figure ...

Page 10: ...T 200SC connection input command ping 192 168 168 125 as shown below If no response received it explains the link has troubles either the connection is not proper or the PC s IP address can not match with CYT 200SC s IP address Set the PC s IP address with CYT 200SC s IP address with same segment if the PC uses fixed IP address the address must be ranged in 192 168 168 1 192 168 168 65 or 192 168 ...

Page 11: ... display a message window for User name and Password the default for user name and Password is admin admin as shown below 4 While the user name and password entered a Web setting interface of CTY 200SC will be showed enter it will then display a Network setting page ...

Page 12: ...ion IP Address Set the IP address of the CYT 200SC default setting is 192 168 168 125 Subnet mask Set the subnet mask of the CYT 200SC default setting is 255 255 255 0 Gateway Set the gateway of the CYT 200SC default setting is 192 168 168 254 Primary DNS Set the DNS of the CYT 200SC default setting is 168 95 1 1 ...

Page 13: ... 11 2 DHCP CLIENT Function instruction Function Description Host Name optional Fill in the host name default setting is CHIYU optional ...

Page 14: ...in the service name optional up to 47 characters Close Connection when Idle Time Over Default setting is 0 second the range is from 0 4294967295 Keep the connection of CYT 200SC and ISP always must set the no into 0 or the connection with PPPoE will be disabled when Idle time over PPPoE with Fixed IP Address After selecting ENABLE fill in fixed IP Default setting is DISABLE optional ...

Page 15: ...ect with monitoring side or the connection will be off automatically when remote idle Access Password Make sure the data secure user must set the code for management User must inset the correct password and process the further procedure after authority up to 31 characters Keep Alive Check Set Enable or Disable keep alive check function default setting is Disable While keep alive check enable the p...

Page 16: ...is blank TCP Connection There are 2 modes to set TCP connection to server 1 Start Up This mode means when CYT 200SC enable it will build the TCP connection with SERVER immediately It will automatically build the TCP connection after disable and then re connect again 2 Any Character This mode means only when CYT 200SC receives data from RS232 422 485 it will build TCP connection with SERVER TCP con...

Page 17: ...e Host IP Address Domain Name Set remote host IP address or domain name default setting is blank Local Listen Port Set the local listen port default setting is 50000 Heart Beat How many seconds to transmit a UDP heart beat to server can be selected It s helpful to know the connection with SERVER enabled Default setting is Disabled and the maximum setting is 65535 seconds ...

Page 18: ...ing side or the connection will be off automatically when remote idle Access Password Make sure the data secure user must set the code for management User must inset the correct password and process the further procedure after authority up to 31 characters Keep Alive Check Set Enable or Disable keep alive check function default setting is Disable While keep alive check enable the pin packet will b...

Page 19: ...is blank TCP Connection There are 2 modes to set TCP connection to server 1 Start Up This mode means when CYT 200SC enable it will build the TCP connection with SERVER immediately It will automatically build the TCP connection after disable and then re connect again 2 Any Character This mode means only when CYT 200SC receives data from RS232 422 485 it will build TCP connection with SERVER TCP con...

Page 20: ...e Host IP Address Domain Name Set remote host IP address or domain name default setting is blank Local Listen Port Set the local listen port default setting is 50000 Heart Beat How many seconds to transmit a UDP heart beat to server can be selected It s helpful to know the connection with SERVER enabled Default setting is Disabled and the maximum setting is 65535 seconds ...

Page 21: ...d Xon Xoff Software flow control CTS RTS Hardware flow control Default setting is None Force Packet Transmit Time 10ms Force packet transmit time The minimum setting is 10ms of setting serial interval between data Default setting is 20ms Force Packet Transmit Length bytes Force packet transmit length The serial set length of data transmission range is from 1 1500bytes Default setting is 1000 Delim...

Page 22: ... Software flow control CTS RTS Hardware flow control Default setting is None Force Packet Transmit Time 10ms Force packet transmit time The minimum setting is 10ms of setting serial interval between data Default setting is 20ms Force Packet Transmit Length bytes Force packet transmit length The serial set length of data transmission range is from 1 1500bytes Default setting is 1000 Delimiter 1 Set...

Page 23: ...word key Fill in the password key for DDNS up to 31 characters Device DNS Name Fill in the device DNS name for example hostname tzo com Registry IP Address Display the registry IP address when DDNS is enabled It will show the registry IP address Status Display DNS Serve status when DDNS server does not enable it will show DDNS function is disabled ...

Page 24: ... the password for DDNS up to 31 characters Device DNS Name Fill in the device DNS name for example hostname dyndns org Registry IP Address Display the registry IP address when DDNS is enabled It will show the registry IP address Status Display DNS Serve status when DDNS server does not enable it will show DDNS function is disabled ...

Page 25: ...name default setting is CHIYU Device Location Fill in the device location default setting is blank Administrator Password User Name Fill in the user name Password Change Change the password for security reasons please fill in a new password to replace the default management Password Confirm Confirm the new password Block Ping Request Select unblock or block ping request function default setting is...

Page 26: ... Default Gateway Display CYT 200SC Default Gateway default setting is 192 168 168 254 Primary DNS Display CYT 200SC Primary DNS address default setting is168 95 1 1 STATUS Display CYT 200SC internet status Serial Status Force Packet Time Length Display Force Packet Time Length default setting is 20ms 1000bytes Baud Rate Display Baud Rate Port1 Port2 default setting is 19200 Data Bits Display Data ...

Page 27: ...uction Function Description Backup After execution can save the present system settings as a backup file and save it in hardware the sub name of the saved file is cfg Restore Browse and select saved file cfg execute Restore to restore system settings ...

Page 28: ...file to upgrade Browse and select firmware execute Upgrade to upgrade firmware Has to assure the possibility of power supply during the process of upgrading or severe damage will be caused What if upgrade different firmware to different products and it will also cause severe damage ...

Page 29: ...T 200SC IP address Destination IP Address Input IP address of Remote Host Packet Number Set up the number of PING package ranged 1 4 the default 4 Ping Size Set up the size of PING package the utmost setting 1460 bytes Ping Result Display Sent Request data Display Receive Reply data ...

Reviews: