(2)PORT 2
Function instruction
Function
Description
Baud Rate
1.Set serial port baud rate, the parameters can be selected
:
1200
、
2400
、
4800
、
9600
、
19200
、
38400
、
57600
、
115200
、
230400 and Others
2.After selecting Others , fill custom baud rate into the user defined
3.Default setting is
19200
Data Bits
Set the data bits
,
5,6,7,8 parameters can be selected, default setting is
8
Parity Check
Set the parity check
,
4 parameters can be selected
:
1.odd
2.Even
3.Mark
4.Space
Default setting is
None
Stop Bits
Set the stop bits
,
1,2 parameters can be selected, default setting is
1
Flow Control
Set the flow control
,
2 parameters can be selected
:
Xon/Xoff
:
Software flow control
CTS/RTS
:
Hardware flow control
Default setting is
None
Force Packet Transmit Time
(10ms)
Force packet transmit time
The minimum setting is 10ms of setting serial interval between data. Default
setting is
20ms
.
Force Packet Transmit
Length (bytes)
Force packet transmit length.
The serial set length of data transmission range is from 1 ~ 1500bytes. Default
setting is
1000
Delimiter 1
Set the transmission data end by identified delimiter and if your transmission
data includes the identified delimiter, CYT-200SC will send out packet at
once.
Default setting is
disabled
. The range is from 0x00 ~ 0xFF
Delimiter 2
Set the transmission data end by identified delimiter and if your transmission
data includes the identified delimiter, CYT-200SC will send out packet at
once.
Default setting is
disabled
. The range is from 0x00 ~ 0xFF