SELF-CONTAINED BREATHING APPARATUS (CTS-IB-PPE-01)
©Chlorine Tech Services (Pty) Ltd
–
CIPC Reg # 2018/101848/07
Rev # 01/2020/10/15
P a g e
| 12
Step 10 (Vacuum Test)
•
Close the cylinder valve and breathe down
(slowly) the system
•
The alarm whistle should sound at +/- 50
bar
•
Continue breathing down the system
•
Once empty, hold breath for 8 seconds
–
the face mask should collapse and hold to
face (indicating a positive seal)
3.4.
Doffing (taking off) the SCBA
Step 1
•
Loosen the chin and cheek straps, by
pressing the buckles forward using your
thumbs
Step 2
•
Reach under and pull the mask off
backwards over your head (do not pull on
the front port).
•
Reset Demand Valve by pushing the
RED button (this will shut the air flow)
•
Close the cylinder valve
•
Vent system by pressing Exhaust Button
•
Check that Pressure Gauge is on Zero
pressure
•
Press Red Button to reset system
Step 3
•
Extend waistbelt straps and open waist
belt buckle
.