15
1. Move the safety switch to the “on” position.
2. Wait 10 seconds for the system to respond.
(
If your system is linked to an automatic ORP controller, we suggest you
turn the system to maximum, which will allow for full production every time
the controller calls for it. If you are running your system manually you will
need to find the point at which you keep a satisfactory level of chlorine in
the water. It may take several days to find this point.
•
If your
ChlorKing®
system is linked to an automatic controller, remember
that it will only work when the controller is in feed mode. It is also a good
idea to make sure that your controller is not set in proportional band mode,
instead try using double set point control (if your controller supports this
function). An example of this is if you want to maintain a 700 ORP, have
the controller set to turn on at 695 ORP and turn off at 705 ORP, that way
your
ChlorKing®
system is not switching on and off all the time.
(Call the manufacturer of your controller if you are having difficulties in
comprehending the saline chlorination system set up instructions. Most
controllers also require a “gold tip” ORP probe when working with a saline
chlorination system.)
Your
ChlorKing®
system operates when power is activated by the main pumps,
and from your ORP controller, and will continue to operate for as long as power
is applied from those two sources.
•
The system has an output range of 5-100% of the rated chlorine
production, and can be adjusted by increasing or decreasing the flow
through the venturi gauge.
7.5 litres / min = 11.34 kg per day
Normal operating amps and volts for this model device are:
NEXGEN
- 100amps @ 23v
•
Water flow through the
ChlorKing®
cell is critical. Please ensure that you
have at least 300 Lpm through the cell to achieve the rated chlorine
production.