2.6 POWER SUPPLY ELECTRICAL CONNECTIONS
WARNING
DO NOT FORGET TO CONNECT THE EARTH TERMINALS AND THE EQUIPMENT
BONDING WIRE. THE ELECTRICAL SUPPLY MUST MATCH THE SYSTEM RATED
CURRENT. ENSURE THAT POWER IS LINKED TO THE MAIN PUMP POWER
SOURCE FOR THE POOL TO ENSURE THAT YOUR
CHLORKING®
NEXGEN
SYSTEM NEVER OPERATES WHEN THE POOL PUMPS ARE OFF.
For ease of service it is recommended that a manual disconnect be installed
between the electrical service and the NEXGEN system.
Connect the electrical supply from the pool equipment room to the connections marked
Line and Ground on the power distribution terminal block. Ensure that the electrical
service is protected by a circuit interrupter and is rated for the model NEXGEN that is
installed.
Connect the blue control cord to a chemical feed controller or for manual operation, into
a 120V electrical outlet protected by a ground fault circuit interrupter.
2.7 BONDING
Connect a minimum 8awg bonding wire to the bonding lug on the bottom of the electrical
enclosure.