2.9 SATURATED SALT FEEDER INSTALLATION
Place the Saturated Salt Feeder tank in an easy to access location. The tank will need
access for adding salt on a continuous basis.
Plumb the peristaltic pump suction line to the salt outlet on the Saturated Salt Feeder
with 1/4 tubing supplied with the peristaltic pump. The salt outlet on the Saturated Salt
Feeder is a small blue and white valve located at the bottom of the salt feeder. Plumb
the Saturated Salt Feeder water supply to the fitting on the chemical metering assembly
using ½ inch tubing.