38
Chapter 4 Operation
Table 4-1 Troubleshooting Table
Warn/Protect/
Fault
Definition Possible
causes
Recommended
solutions
Warn
1
、
CommErr
Communication
inside inverter fails
1
、
Internal wiring
problem of the
inverter;
2
、
LCD display
software problem
1
、
Observe for 5
minutes and see
whether the alarm will
be eliminated
automatically;
2
、
Check the inverter;
3
、
Contact after-sales
service personnel
2
、
Warn001x
Fan on DC side
(invisible from
outside) inside
inverter is
working
abnormally
1
、
Fan is blocked;
2
、
Power supply
circuit of the fan has
problem;
3
、
Fan state test
circuit has problem;
4
、
Fan service life
expires
1
、
Observe for 5
minutes and see
whether the alarm will
be eliminated
automatically;
2
、
Check the inverter;
3
、
Contact after-sales
service personnel
3
、
Warn002x
Fan on AC side
(invisible from
outside) inside
inverter is
working
abnormally
1
、
Fan is blocked;
2
、
Power supply
circuit of the fan has
problem;
3
、
Fan state test
circuit has problem;
4
、
Fan service life
expires
1
、
Observe for 5
minutes and see
whether the alarm will
be eliminated
automatically;
2
、
Check the inverter;
3
、
Contact after-sales
service personnel
4
、
Warn003x Inside
warning
Internal storage
works abnormally
1
、
Observe for 5
minutes and see
whether the alarm will
be eliminated
automatically;
2
、
Contact after-sales
service personnel