39
Residual
Current
Abnormal
The
insulation
resistance
against
the
ground
at
the
input
side
decreases
during
the
inverter
operation
,
which
causes
excessively
high
residual
current
.
1
.
If
the
alarm
occurs
accidentally
,
possibly
the
external
circuits
are
abnormal
accidentally
.
The
inverter
automatically
recovers
to
the
normal
operating
status
after
the
fault
is
rectified
.
2
.
If
the
alarm
occurs
repeatedly
or
lasts
a
long
time
,
check
whether
the
insulation
resistance
against
the
ground
of
PC
strings
is
too
low
.
PV
Strings
Abnormal
PV
strings
have
been
shielded
for
a
long
time
.
PV
strings
are
deteriorating
.
1
.
Check
whether
the
PV
string
is
shielded
.
2
.
If
the
PV
string
is
clean
and
not
shielded
,
check
whether
the
PV
modules
are
aging
or
deteriorated
.
PV
Strings
Reverse
The
cables
of
PV
strings
are
connected
reversely
during
the
inverter
installation
.
Check
whether
the
cables
of
PV
strings
are
correctly
connected
.
If
they
are
connected
reversely
,
reconnect
the
cables
.
BUS
Under
Voltage
BUS
Over
Voltage
Invert
Module
Fault
BOOST
Fault
EEPROM
Fault
Abnormal
internal
energy
control
imbalance
has
been
triggered
by
the
PV
Strings/grid
sharp
change
of
working
conditions
EEPROM
Component
damaged
1
.
If
the
alarm
occurs
occasionally
,
the
inverter
can
automatically
recover
to
the
normal
operating
status
after
the
fault
is
rectified
.
2
.
If
the
alarm
occurs
repeatedly
,
contact
your
dealer
for
technical
support
.
Replace
the
monitoring
board
.
Zero
power
generation
and
Yellow alarm light
illuminating
in
remote
monitor
system
Communications
outage
If
modem
or
other
data
logger
is
used
,
please
reboot
it
;
if
still
does
not
work
after
rebooting
,
contact
your
dealer
.
CPS SCA-S/
SM Series Inverter