Drop Feeder Control
5
MA922F
Time Clock Features and Operation
• The outside edge of the clock face is a series of tabs.
• Use a finger nail of small screw driver to push tabs out.
• Each white tab on the time clock is equivalent to 15 minutes.
• Turn the white minute hand clockwise until the real time (actual time of day) is lined up with white arrow on
inner clock face.
•
Do not turn the hand counter-clockwise! This will strip out the nylon gears and void your warranty.
Also, never adjust the time clock by turning the outer dial.
Drop Feeder Control (with Single Linear Actuator) Wiring Diagram
Time of Day (AM & PM Format)
Pull tabs as required for feeding cycle
(1hr. shown)
When adjusting, turn minute hand
clockwise only.
Figure 2. Setting Time Clock