36" Galvanized Belt Drive HYFLO
®
Fans
Installation and Operators Instruction Manual Fan
Part No. 53096-52
z
Fan and Fan Framing Dimensions
MV1747-017 04/03
4
Planning the layout of the spacing between Fans is very
important. Spacing too close together will cause
interference between the discharge Cones.
The Rough
Opening dimensions for Fans are shown above
.
6
3
1
2
7
Item
Description
Dimension
1
Bottom Length
41-1/2'' [105.41cm]
2
Vertical Dim. of Cone
1'' [2.54cm]
3
Height (Outside of Flanges) 45-1/2" [115.57cm]
4
Rough Opening Width
43" [109.22cm]
5
Rough Opening Height
42-1/2 [107.95cm]
6
Minimum Spacing
3-1/2" [8.89cm]
7
Outside Diameter of Cone
43-3/4" [111.13cm]
8
Depth inside Building
6-1/2" [16.51cm]
Figure 1. Fan Dimensions
5
8
The Fan Inlet and exhaust must be kept clear of obstructions. Failure to keep the Fan airflow path
clear of obstructions could cause loss of Fan performance and Fan damage.
MV2386E
April 2018
Do Not
operate these Fans with a variable speed control device. Operating static pressure should be less
than 0.15 inches water column [37.4 pascal].