Fan Installation
48'' Belt Drive Cone Fan
8
MV1600B
Important!
The 48'' Cone Fan must be installed in a side wall.
Build fan framing out of 2''
[50 mm]
lumber (not supplied). The required rough
opening is provided in the table below.
Insert the Fan Assembly in the framed opening in the side wall
Center the Fan Assembly in the framed opening, left to right. Allow the Fan Housing
to set on the bottom of the framed opening.
Secure the Fan Assembly to the framed opening, using the included 1/4'' x 1-3/4'' Lag
Screws starting with the center holes in each panel. The end holes will also be used
for attaching the Corner Flange Angles.
Fan Installation
MV1600-007 6/99
A
B
MV1600-008B 6/99
Figure 3. Fan (side view)
C
D
E
F
Figure 2. Framing Diagram
(front view)
Table 1. Framing Size
A
Rough
Opening
B
Rough
Opening
C
D
E
F
55"
57 1/2"
33-3/8"
60-7/8" x 58.3"
5-3/4"
21"