Fan and Fan Framing Dimensions
2
MV1864P
Planning the layout of the spacing between fans is very important. A Minimum of 13" between Fan rough openings
is required so the Cones do not interfere. Dimensions for rough openings for Fans are shown in
Figure 2 below
.
Important!
The Fan Inlet and exhaust must be kept clear of obstructions. Failure to keep the Fan airflow path clear
of obstructions could cause loss of Fan perfomance and Fan damage.
Do Not
operate these Fans with a variable speed control device. Operating static pressure should be less than 0.15
inches water column.
Fan and Fan Framing Dimensions
3
4
1
5
Item Description
1
59” [149.86 cm]
2
67.81" [172.2 cm]
3
53” [134.91 cm]
4
7.5" [19.1 cm]
5
59" [149.86 cm]
6
8.3 [21.11 cm]
6
Figure 1. Fan and Framing Dimensions
2
MT1864-036 2/05
Figure 2. Rough opening Spacing
2
2
1
Item Dimension
1
13" [33 cm] Min. for round Cones
2
56-1/2" [143.51 cm]