Wiring
48" and 52" Vanguard Plus Belt Drive Fans Installation and Operators Instruction Manual
4
MV1758C
1. Install an electrical disconnect within reach of each Fan
installed.
2.Remove the Motor Access Cover.
3. Remove the electrical knock-out nearest the Fan power
supply outlet.
4. Install the Romex Connector and cord through the knock-
out selected before wiring the motor. Connect the cord to
the motor according to the wiring diagram on the motor.
Verify that the motor is connected for counter clockwise
rotation (viewing the back of the motor, opposite the shaft
end.)
Follow local, state, and national electrical codes for
wiring.
5.Attach the cord to the Top Panel of the Fan using the Cord
Clip, to keep the cord off the Shutter.
6.Allow enough slack in the cord to form a "drip loop" for
moisture to fall away from the cord and not run into the
motor.
7.Remove the slack in the cord between the Cord Clip and the Romex Connector and then tighten the Romex Connector.
The Bottom Panel is designed with 3 tabs,
(Item 1, Figure below)
, to hold the Shutter. Slide the bottom of the Shutter
into the Tabs, lean the Shutter into the Fan and lock the Shutter in place by rotating the (5) Shutter Clips
(Item 2).
Check the Shutter for proper operation. The Shutter Louvers must be able to open and close freely.
Wiring
Shutter Installation
2
3
4
Item
Description
1
Motor Access Cover
2
Drip Loop
3
Romex Connector
4
Cord Clip
1
Item
Description
1
Tabs
2
Shutter Clips
2
1