Section 2: Service Guidelines
Entero RPMSP/RPMWU/RPMHD-LED01 Service Manual
2-5
020-100368-05 Rev. 1 (06-2012)
2.3.1 Guidelines for Cleaning
COMPONENTS
PREVENTATIVE
MEASURES
CLEANING TECHNIQUE
Illumination Optics
System, general
Do not
touch or blow on
exposed components. Wear
gloves (supplied).
Use ionized pneumatic guns only. Keep
imaging components and yourself
grounded at all times.
Illumination System,
internal lenses/prisms
Do not
touch or blow on
interior components. Wear
gloves (supplied).
NOTE:
Normally the internal
parts should not be accessed.
Blow off particles with clean, dry
de-ionized air. If necessary, wipe in a
single direction with a clean high quality
optical cloth.
Light Engine
components
Do not
touch or blow on
components. Wear gloves
(supplied).
Blow off particles with clean, dry
de-ionized air. If necessary, use a split
Q-tip with pure isopropyl alcohol on the
glass surface.
Light Engine, DMD
panels
Do not
touch or blow on the
panels.
Blow off particles with clean, dry
de-ionized air.
Projection Lens
To avoid the risk of scratching
the lens, only clean the lenses if
absolutely required. A small
amount of dust on the lenses
will have very little effect on
picture quality. The projection
lens should be free of dust and
fingerprints. If the lenses must
be cleaned, use a DRY soft
cotton cloth. Rub gently in a
circular motion.
Use filtered compressed air to blow out
dust. Remove fingerprints or dirt with
Melles Griot Cleaning Fluid
18LAB011(or equivalent) and a clean
lint-free cloth.