3-34
M Series User Manual
020-100009-05 Rev. 1 (09-2010)
Section 3: Operation
•
AUTO POWER UP
If there is an AC power interruption, while Auto Power Up is enabled, the projector will resume operation in
the same state as it left off. If the lamps are on and an image showing when AC power is lost, the projector will
automatically power back up with the lamps on and an image will show when AC is restored.
•
AUTO SHUTDOWN ENABLE
When Auto Shutdown Mode has been selected, and no projector activity has been seen for the activation time-
out period, the projector will enter a power saving mode in which the lamps will dim and the shutter will close.
If this condition persists for an additional time-out period, the projector will automatically go to Standby mode.
The presence of any activity within this combined interval will cancel Auto Shutdown and return the projector
to normal operation.
•
TURN OFF IMAGE AFTER (min)
This sets the activation interval (in minutes) for Auto Shutdown. If all activity (input signals, web or serial port
activity, key presses) is lost for this length of time, and Auto Shutdown is enabled, an Auto Shutdown cycle
will begin.
•
ENTER STANDBY AFTER (min)
This sets the interval (in minutes) between starting Auto Shutdown and entering Standby mode. Once Auto
Shutdown has been entered, and all activity continues to be absent for this interval, the projector will
automatically enter power Standby mode.
•
LAMP REGENERATION START TIME
For 24/7 operation, the lamp regeneration cycle is required or lamp life will be reduced. This control allows
you to set the time of day (in 24 hour format) when the regeneration cycle will start. In Dual Lamp mode, the
cycle will be performed on each lamp separately. The second lamp will wait for the first lamp to come back on
before it begins the cycle. In single lamp mode, the projector will go into Standby mode for the regeneration
cycle. The regeneration cycle will run for 15 minutes for each lamp. The lamp(s) must run for a minimum of 24
hours or the regeneration cycle will be skipped.
•
OVER-TEMP FAN ASSIST
When enabled, this option will cause all fans to come on at full speed if any enabled thermal sensor has an
over-temperature fault. This may help to prevent an emergency shutdown if the extra cooling can bring the
temperature within limits before the shutdown occurs. The fan assist will cause increased noise levels due to
the simultaneous full speed operation of all the fans. Normal operation will resume when all over-temperature
conditions are removed or fan assist is turned off.
DATE & TIME - S
UBMENU
The current year-month-day, hour-minute-second. Changes here reset the projector’s real-time clock.
MENU PREFERENCES - S
UBMENU
Adjust the appearance, content and/or location of on-screen menus and messages.
•
LARGE MENU FONT
Enter a checkmark to enlarge menus and their text. To adjust Menu Location to accommodate the increased
menu area.
Summary of Contents for M Series
Page 1: ...M Series U S E R M A N U A L 020 100009 05 ...
Page 2: ......
Page 3: ...M Series U S E R M A N U A L 020 100009 05 ...
Page 14: ......
Page 46: ......
Page 120: ......
Page 131: ...Section 6 Troubleshooting M Series User Manual 6 7 020 100009 05 Rev 1 09 2010 FIGURE 6 1 ...
Page 132: ......
Page 148: ......
Page 152: ......
Page 167: ......