Section 3: Operation
M Series User Manual
3-53
020-100009-05 Rev. 1 (09-2010)
SINGLE LAMP SWITCH ON FAIL
Selecting this check box causes the projector to automatically attempt to start the other lamp if the current lamp
experiences problems, and is preventing a light on the wall. This applies if there is a failure to start a lamp, or a
failure during operation. This feature applies only to systems which have multiple lamps and are currently set
to run in a single lamp operating mode. A brief period with no light may occur before the other lamp becomes
active.
DYNAMIC IRIS - S
UBMENU
Refer to
Section Appendix A: Menu Tree.
WARN WHEN LAMP REACHES (HOURS)
Enter the maximum number of hours (threshold) for lamp usage. When the threshold (set number of hours) is
reached on either lamp, a warning message displays on the status system, indicating that the lamp should be
changed. This setting is user-defined only, has no bearing on lamp warranty, and is not tied to actual lamp life
in any way. The default setting is 0, which means that the feature is off, and no warning will be generated.
LAMP 1 s/n and LAMP 2 s/n
Enter the serial number for the specified lamp. This will apply the serial number to the current lamp statistics
file. It will not perform the archiving as done by the
CHANGE LAMP
function.
CHANGE LAMP - Submenu
Initiates the lamp change process for the selected lamp and allows the serial number of the new lamp to be
entered.
Lamp serial numbers are used for keeping statistics on each lamp used in each lamp position. Entering of serial
numbers is optional, but is recommended.
When using this function, the statistics from the previous lamp are archived, and starts statistics tracking for
the new lamp. If this function is not used, statistics are accumulated (combined) for both the new and old
lamps.
LAMP 1 HISTORY and LAMP 2 HISTORY
Lists the serial number and the number of hours logged for each lamp (current and previously) installed in the
projector. The current lamp appears at the bottom of the list. This entry is added automatically when you record
a new serial number during the lamp change process. See
CHANGE LAMP - Submenu
.
Summary of Contents for M Series
Page 1: ...M Series U S E R M A N U A L 020 100009 05 ...
Page 2: ......
Page 3: ...M Series U S E R M A N U A L 020 100009 05 ...
Page 14: ......
Page 46: ......
Page 120: ......
Page 131: ...Section 6 Troubleshooting M Series User Manual 6 7 020 100009 05 Rev 1 09 2010 FIGURE 6 1 ...
Page 132: ......
Page 148: ......
Page 152: ......
Page 167: ......