Maintenance and cleaning
Maintain the cleanliness of all internal components during any service procedure. All of the projector
optics must remain free of contaminants to perform at the level specified. Even a small amount of dust
or a fingerprint may degrade the image or cause a noticeable reduction of brightness.
Always power down and disconnect/disengage all power sources to the projector before servicing or
cleaning the lens or before any of the projection head covers or doors are loosened and removed. If
the seal is broken while the intake fans are still operating, internal components are immediately
vulnerable to contamination from inbound particles.
Notice. If not avoided, the following could result in property damage.
•
Avoid touching optical elements.
•
Always wear clean, lint-free gloves when handling the product.
Guidelines for cleaning
Use the following guidelines when cleaning components.
Component
Preventative measures
How to clean
Lamp
Wear protective gear approved by
Christie, and handle by the lamp
housing only. Never grip the glass
portion of the lamp.
Fingerprints reduce
output quality and
shorten lamp life.
Remove any contaminants with pure
isopropyl alcohol and a clean lint-
free cloth.
Illumination Optics System
Never touch or blow on exposed
components. Wear gloves
(supplied).
Use ionized pneumatic guns only.
Keep imaging components and
yourself grounded at all times.
Integrator
Never disassemble the integrator
module.
Blow off particles with clean, dry de-
ionized air.
Illumination system, internal lenses/
prisms
Never touch or blow on interior
components. Wear gloves
(supplied).
Normally the internal
parts should not be
accessed.
Blow off particles with clean, dry de-
ionized air. If necessary, wipe in a
single direction with a clean high
quality optical cloth.
Light engine components
Never touch or blow on components.
Wear gloves (supplied).
Blow off particles with clean, dry de-
ionized air. If necessary, use a Q-tip
with pure isopropyl alcohol on the
glass surface. Never touch the
imaging panels. The green imaging
panel also has glass behind it.
Service guidelines
M Series Service Guide
14