Warning! If not avoided, the following could result in death or serious injury.
•
UV EXPOSURE! Protective UV safety glasses with side shields and Christie approved protective
safety clothing must be worn when performing optical adjustments or servicing the product.
•
EXPLOSION HAZARD! Allow sufficient time for the lamp to cool down before powering down the
product, disconnecting it from AC, and opening the lamp door.
1. Open the lamp doors by unscrewing the captive screw.
2. Unscrew the three captive screws securing each lamp.
200W and 350W
450W
3. Slowly slide the lamp out of the compartment.
4. For the second lamp, repeat steps 1 to 3.
5. Check the aluminum tape on the lamp door. If there are any signs of adherence degradation,
replace the tape.
Installing the lamps
If replacing lamps due to a lamp explosion; both lamps should be removed from the lamp housing
area, including fan #4 and exhaust ducts. Ensure they are carefully vacuumed before lamp
replacement.
Estimated replacement time: 3 minutes per lamp.
Warning! If not avoided, the following could result in death or serious injury.
•
UV EXPOSURE! Protective UV safety glasses with side shields and Christie approved protective
safety clothing must be worn when performing optical adjustments or servicing the product.
1. Carefully insert the lamp into the lamp housing with the connector oriented to the top.
2. Seat the lamp onto the mating connector in the projector and push the lamp forward until fully
seated.
Optics
M Series Service Guide
82
020-100551-11 Rev. 1 (01-2019)
Copyright
©
2019 Christie Digital Systems USA, Inc. All rights reserved.