3. Secure the lamp with the three captive screws.
4. Close and secure the lamp door.
Disposing of the lamp
The lamp is extremely hazardous. Do not dispose of in regular trash.
For warranty claims:
1. Carefully repack the lamp with the original shipping material and carton.
2. Enclose the completed RMA claim form that came with the lamp.
3. Ship the lamp to the nearest Christie service depot for evaluation.
For safe disposal:
1. Pack the lamp into its original carton (without the packaging material).
2. Tape the box up securely along its seams.
3. Discard as industrial waste, in accordance with your local regulations.
Removing the light engine
The light engine is located inside the light engine cover. The engine is secured by three screws holding
it to the base plate. The light engine can be removed without having to remove the entire optical
assembly.
Estimated replacement time: 40 minutes.
Caution! If not avoided, the following could result in minor or moderate injury.
•
Observe all electrostatic precautions. Use a grounded wrist strap and insulated tools when
handling, servicing, or cleaning electronic assemblies.
1. Remove the top cover (on page 45).
2. Remove the light engine intake duct (on page 81).
3. Remove the card cage lid (on page 59).
4. Disconnect fans #5 and #6 located on the light engine cover at the quick disconnect coupling.
5. Remove the seven screws from the light engine cover to allow the top portion of the housing to
be removed.