IP ADDRESS:
Enter a valid and unique IP address for use on the network to which the
projector is currently connected. This address will overwrite any previous IP address
such as the projector’s factory-defined default (0.0.0.0), or one that has been assigned
by a DHCP server or other user. It takes approximately 10 seconds for the projector
to respond at its new address.
PORT:
On some Ethernet networks, firewall restrictions may require that the port
number of the projector be changed from its default of 3002. If so, enter a new valid
port number here. It is highly recommended not to use a valid port number below
1024, as these ports are typically reserved for and used by common IP applications.
SUBNET MASK AND DEFAULT GATEWAY:
The Subnet Mask and Default Gateway are
automatically assigned when DHCP is enabled. If a static IP is being used, the IP
must be assigned first since the projector estimates the subnet mask after the IP is
entered. The Default Gateway is an optional router device used to send and receive
data outside the subnet.
ArtNet Interface
Settings
—
SUBMENU
ArtNet is an Ethernet
communication protocol
that was developed by
Artistic Licence. It is
used for controlling
lighting/staging
equipment from a
lighting console or PC application. It is based on the popular DMX512 control
protocol.
ArtNet SUBNET:
This is the highest level address for a device. Typically it is set to 0.
ArtNet UNIVERSE:
Each packet of data is broadcasted to all devices plugged into a
universe (up to 512 devices/channels).
ArtNet CHANNEL:
There are 512 channels per universe. This control allows you to
specify the starting channel for this projector.
ArtNet ADVANCED MODE:
When this setting is enabled, each projector listens for data
on 64 channels starting with the base channel. When advanced mode is not in use, the
projector only listens on 10 channels. You can squeeze more devices per universe
when the projector uses fewer channels.
NOTE:
The additional 54 functions are not currently implemented and are reserved