background image

4. Level the wall mount and mark the center of the four mounting holes.

5. Drill four 5/32" (4 mm) diameter holes 2.5" (64 mm) deep.
6. Tighten the four #14 x 2.5" wood screws so that the wall plate is firmly attached, but do not

over-tighten.
Never tighten in excess of 80 in-lbs (9Nm).

Installing the mount to solid concrete or cinder block

Learn how to install the wall mounts onto solid concrete or cinder block walls.

Warning! Failure to comply with the following could result in death or serious injury.

Concrete must be a minimum of 2000 psi density. Lighter density concrete may not hold the
concrete anchor.

The supporting structure must safely support the combined load of the product, all attached
hardware, and components following all local safety standards and regulations.

When installing wall mounts onto cinder blocks, verify that you have a minimum of 1-3/8" (35 mm) of
actual concrete thickness in the hole to be used for the concrete anchors. Cinder block must meet
ASTM C-90 specifications and a minimum nominal width of 8".

1. Place the pull out mount assembly on the wall to use as a template, and verify the pull out

mount is level.

2. Mark the center of the four mounting holes.

3. Use a standard electric drill on slow setting to drill four 5/16” (8 mm) diameter holes to a

minimum depth of 2.5” (64 mm).
To avoid breaking out the back of the hole when entering a void or cavity, do not use a
hammer drill. On cinder block walls, mount in a solid part of the block, generally 1" (25 mm)
minimum from the side of the block. Do not drill into mortar joints.

4. Insert anchors into the holes flush with the wall.

Never attach concrete expansion anchors to concrete covered with plaster, drywall, or other
finishing material. If mounting to concrete surfaces covered with a finishing surface is
unavoidable, the finishing surface must be counter bored, as shown in the image below.

5. Place the pull out mount assembly over the anchors and secure it with four #14 x 2.5” screws.

Make sure concrete anchors do not pull away from the concrete when tightening screws. If the
wall is covered with plaster, drywall, or other finishing material thicker than 5/8" (16 mm),
custom fasteners must be supplied by the installer.

6. Tighten the four #14 x 2.5" wood screws so that the wall plate is firmly attached, but do not

over-tighten.
Never tighten in excess of 80 in-lbs (9Nm).

Installing flat panels on the ML20 wall mount

Installing Flat Panels on the ML20 Wall Mount Instruction Sheet

6

020-102525-01 Rev. 1 (02-2017)

Copyright 

©

 2017 Christie Digital Systems USA Inc. All rights reserved.

Summary of Contents for ML20

Page 1: ...he X Y and Z axis alignment Features Use the ML20 wall mounts to hang and adjust the flat panels and to access the rear of the panels Modular mount for large video wall display configurations Adjustments of panels for optimal gaps Spring loaded mechanisms secure displays Pull out prop open mechanism provides quick service access Installing Flat Panels on the ML20 Wall Mount Instruction Sheet 1 020...

Page 2: ...the screen from its sides Christie products must be installed and serviced by Christie qualified technicians Caution Failure to comply with the following could result in minor or moderate injury Do not over tighten hardware This product is intended for indoor use only Do not exceed the maximum load capacity of the product Types of installations Learn the supported surfaces for installing the wall ...

Page 3: ...2 5 wood screw Qty 5 Required tools Ensure the appropriate tools are available during the installation Phillips screwdriver Socket wrench Pencil Drill 3 8 socket 5 16 8 mm bit for concrete and cinder block walls 5 32 4 mm bit for wood stud walls Level Installing flat panels on the ML20 wall mount Installing Flat Panels on the ML20 Wall Mount Instruction Sheet 3 020 102525 01 Rev 1 02 2017 Copyrigh...

Page 4: ...ount must be fully collapsed For the FHD553 XE panel the wall mount must be fully expanded 4 Tighten the washer and nuts 5 Repeat steps 1 to 4 for the bottom cross bar Installing the wall mount Learn how to install the wall mounts onto different surfaces The maximum load capacity of the wall mount is 75 lbs 34 kg When installing the wall mounts ensure there is proper spacing between the mounts to ...

Page 5: ...Hardware provided is for attaching the mount through standard thickness drywall into plywood Installers are responsible for providing the hardware for other types of mounting situations When installing the wall mounts on a wood stud wall covered with plywood verify that the wood studs are a minimum of 2 x 4 nominal size and plywood is a minimum 1 2 13 mm thickness Plywood may be covered by drywall...

Page 6: ... holes 3 Use a standard electric drill on slow setting to drill four 5 16 8 mm diameter holes to a minimum depth of 2 5 64 mm To avoid breaking out the back of the hole when entering a void or cavity do not use a hammer drill On cinder block walls mount in a solid part of the block generally 1 25 mm minimum from the side of the block Do not drill into mortar joints 4 Insert anchors into the holes ...

Page 7: ...nel with the brackets onto the wall mount 1 Hang the adapter brackets onto the wall mount and slide into position 2 Loosely fasten the panel in place using the security screw 3 To lock the panel in place use a Phillips screwdriver to tighten the security screws Adjusting the panel up and down Use the height adjustment screw to move the panel up and down 1 Loosen the security screws 2 Turn the heig...

Page 8: ...urn the adjustment wheel clockwise to move the corner out from the wall mount 2 Turn the adjustment wheel counter clockwise to move the corner towards the wall mount Installing flat panels on the ML20 wall mount Installing Flat Panels on the ML20 Wall Mount Instruction Sheet 8 020 102525 01 Rev 1 02 2017 Copyright 2017 Christie Digital Systems USA Inc All rights reserved ...

Page 9: ...e panel pull the panel away from the wall mount 1 To pull the LCD panel away from the wall mount lift the locking tabs To access the locking tabs for a mount it may be necessary to extend the adapter brackets of the LCD panels above it To avoid damaging the LCD panel always release both locking tabs at the same time and move the panel forwards evenly Installing flat panels on the ML20 wall mount I...

Page 10: ...nical support for Christie products is available at North and South America 1 800 221 8025 or Support Americas christiedigital com Europe Middle East and Africa 44 0 1189 778111 or Support EMEA christiedigital com Asia Pacific 65 6877 8737 or Support APAC christiedigital com Installing flat panels on the ML20 wall mount Installing Flat Panels on the ML20 Wall Mount Instruction Sheet 10 020 102525 ...

Reviews: