Programmable DC Power Supply (with Solar Array Simulation) 62000H Series
Operating & Programming Manual
3-92
3.
I-V Curve Programming Response Time (Typical)
62050H-600S
Delta V= 600 to 0V
(1s @ No Load)
(40ms @ 500W )
(8ms @ 2500W )
Delta V=350 to 250V
(160ms @ No Load)
(6.6ms @ 500W )
(1.4ms @ 2500W )
62100H-600S
Delta V= 600 to 0V
(1s @ No Load)
(40ms @ 1000W )
(8ms @ 5000W )
Delta V=350 to 250V
(160ms @ No Load)
(6.6ms @ 1000W )
(1.4ms @ 5000W )
62150H-600S
Delta V= 600 to 0V
(1s @ No Load)
(40ms @ 1500W )
(8ms @ 7500W )
Delta V=350 to 250V
(160ms @ No Load)
(6.6ms @ 1500W )
(1.4ms @ 7500W )
62150H-1000S
Delta V= 1000 to 0V
(1.5s @ No Load)
(40ms @ 1500W )
(8ms @ 7500W )
Delta V=580 to 420V
(240ms @ No Load)
(6.4ms @ 1500W )
(1.3ms @ 7500W )
A620028
Delta V= 1000 to 0V
(1.5s @ No Load)
(40ms @ 1500W )
(8ms @ 7500W )
Delta V=580 to 420V
(240ms @ No Load)
(6.4ms @ 1500W )
(1.3ms @ 7500W )
A620027
Delta V= 600 to 0V
(1s @ No Load)
(40ms @ 1500W )
(8ms @ 7500W )
Delta V=350 to 250V
(160ms @ No Load)
(6.6ms @ 1500W )
(1.4ms @ 7500W )
62020H-150S
Delta V= 150 to 0V
(120ms @ No Load)
(16ms @ 200W )