Programmable DC Power Supply (with Solar Array Simulation) 62000H Series
Operating & Programming Manual
1-2
1.2.3
Output/Indication
(1) Auxiliary power output (12Vdc/10mA).
(2) Analog monitors (V/I Monitor) the output signal instantaneously. This allows signals to
be easily monitored by external instruments (DMM, Oscilloscope, etc). Able to set the
output level indication (DC ON) signal.
(3) Output indicator (DC ON) signal.
(4) Protection state indication (OVP/OCP/OPP /FAN LOCK/AC FAULT, etc).
(5) Over temperature (OTP) protection signal.
(6) CV/CC status indicators.
(7) Output status indicators.
1.2.4
Input Control Signals
(1) Remote sense input for voltage drop compensation.
(2) Analog reference voltage (APG) input in which the setting of voltage and current can be
set by the voltage source, current source and resistance that adjusted for the panel
setting.
(3) Remote inhibit control signal (TTL)
1.2.5
Measuring & Editing
(1) Measurement for voltage, current and power.
(2) 10 programs and 100 sequences to edit voltage/current waveform output.
(3) One run time voltage program that can be set for long hour.
(4) 10 programs and 100 sequences to edit I-V curve waveform output.
1.3
Specifications
Chroma 62000H Series High Power Density DC Power Supplies with Solar Array Simulation
contain 2KW (62020H), 5KW (62050H), 10KW (62100H) and 15KW (62150H) 4 sub-series
by the output power and the power supply of each sub-series has various output
specifications. Table 1-1 lists the output specifications of 62000H Series DC POWER
SUPPLIES with Solar Array Simulation 2KW, 5KW, 10KW and 15KW. (It is suggested to
warm up 10 minutes or more to begin the tests. The operation of DC Power Supply for output
voltage must be 5% larger than full-scale. The test condition is 25
5°C and under
resistance load.)