Overview
1-9
and 440/480 Vac 3 types of input voltage for selection. There is also a
single phase power supply 200/240 Vac, 2KW model available for selection.
The user can follow the local voltage regulation to select a proper voltage
spec. The Power Supply is set with the required input voltage when
shipped and when the input voltage is not within the range, it will show
AC_fault protection and shut down the output.
18. It is the chassis size without any accessories.
CAUTION
1.
If it is applied to battery charge or inductance load such as motors,
the output port needs to connect a diode in series to prevent the
load current from backwash and damage the device interior, see
Figure 1-1.
2.
For switchable power load applications, if the output load cable is
longer (>20cm) it is suggested to strand the load cable and parallel
the capacitance at the load power input to prevent any unexpected
oscillation from occurring, see Figure 1-2.
3.
For load application, it can parallel connect the capacitor more than
100uF to the load input to avoid any unexpected oscillation from
occurring
4.
Do not bond the external input, output cable and communication
cable all together to avoid interference and cause device error.
Figure 1-1
Figure 1-2
WARNING
Voltage from the two output terminals to earth varies with the 62000H
Series Models with Solar Array Simulation as Table 1-4 shows below:
Table 1-4
Model
Max. Voltage (Vdc) Difference
between Output Terminal and Earth