Programmable DC Power Supply (with Solar Array Simulation) 62000H Series
Operating & Programming Manual
2-10
2.5.2
Specification of Connecting Wire
The maximum inductance of connecting wire to the source is 2μH (the total inductance of two
wires after twisted or processed otherwise including self-inductance and mutual inductance).
CAUTION
1.
To ensure the system’s stability, the cable inductance should not
exceed
2μH. If the UUT input capacitance is too small (smaller
than 100uF), the inductance of UUT input should consolidate. The
maximum inductance of certain single model such as
62150H-1000S (380/400Vac, 440/480Vac) and A620028
(380/400Vac, 440/480Vac) can up to 2mH. It can be identified by
the sticker labeled 2mH on top of the output cover as Figure 2-12
shows. For other models with the needs, please contact Chrom
a’s
agent.
2.
Do not use the wire with extra thin diameter to avoid overheating
and causing hazard.
Figure 2-12
2.5.3
Specification of Parallel Capacitance
The parallel capacitance for output varies with the 62000H Series Models as Table 2-2
shows.
Table 2-2
Model
Max. Parallel Capacitance for Output (uF)
62050H-600S
1350
62100H-600S
2700
62150H-600S
4050
62150H-1000S
1350
A620028
1350
A620027
4050
62020H-150S
10000
CAUTION
1.
To ensure the system’s stability, the capacitance should not exceed
the value listed in Table 2-2.
2.
Be aware of the polarity and its withstand voltage when paralleling
capacitance.