Programmable DC Power Supply (with Solar Array Simulation) 62000H Series
Operating & Programming Manual
3-6
3.
Press “
ENTER
” to confirm.
4.
For
APG ISET
, use the numeric keys
0
~
4
or “Rotary” (
) to set the
mode. There are 5 selections for APG ISET which are NONE / Vref(0-5V) / Vref(0-10V) /
Iref(4-20mA) / Rref(0-5KOhm), where:
NONE: It means not using the programming function.
Vref (0-5V): It means using the external voltage source as the programming setting.
Vref (0-10V): It means using the external voltage source as the programming setting.
Iref (4-20mA): It means using the external voltage current source as the programming
setting.
Rref(0-5KOhm): It means using the external resistance as the programming setting.
5.
Press “
ENTER
” to confirm.
6.
For
APG VMEAS,
use the numeric keys
0
~
3
or “Rotary” (
) to set the
mode. There are 4 selections for APG VMEAS which are NONE / Vref(0-5V) /
Vref(0-10V) / Iref(4-20mA), where:
NONE: It means not using the measurement function.
Vref (0-5V): It means using the power supply output voltage source as the measurement
result.
Vref (0-10V): It means using the power supply output voltage source as the
measurement result.
Iref (4-20mA): It means using the power supply output current source as the
measurement result.
7.
Press
“
ENTER
” to confirm.
8.
For
APG IMEAS
, use the numeric keys
0
~
3
or “Rotary” (
) to set the
mode. There are 4 selections for APG IMEAS which are NONE / Vref(0-5V) / Vref(0-10V)
/ Iref(4-20mA), where:
NONE: It means not using the measurement function.
Vref (0-5V): It means using the power supply output voltage source as the measurement
result.
Vref (0-10V): It means using the power supply output voltage source as the
measurement result.
Iref (4-20mA): It means using the power supply output current source as the
9.
Press “
ENTER
” to confirm.
10. Press
“
EXIT
” to return to the MAIN PAGE.
1.
APG VSET/APG ISET
has 5 selections which are NONE / Vref(0-5V) /
Vref(0-10V) / Iref(4-20mA)/ Rref(0-5KOhm), where
:
a. When selecting Vref=5V
it means the DC Power Supply’s output
0V ~ 600V/0A ~ 25A will map to 0~5V as Figure 3-7(a) shows.
b. When selecting Vref=10V
it means the DC Power Supply’s output