Programmable DC Power Supply (with Solar Array Simulation) 62000H Series
Operating & Programming Manual
3-26
[ S E R I E S / P A R A L L E L ]
M A S T E R O R S L A V E
= S L A V E 1 _
M / S T E R M I N A T O R
= D I S A B L E
Figure 3-38
4.
Use
“
”, “
” keys to move the cursor to the M/S TERMINATOR selection
item.
5.
Use the numeric (
1
~
0
) key or “Rotary” (
) knob to ENABLE or DISABLE
the TERMINATOR as Figure 3-38 shows.
6.
Press “
ENTER
” to confirm.
7.
Press “
EXIT
” to return to the MAIN PAGE.
3.3.3.3.2
Setting MASTER
If MASTER OR SLAVE is set to MASTER, it has to set M/S TERMINATOR, PARALLEL OR
SERIES and NUM. OF SLAVE selections. See the description of PARALLEL OR SERIES in
section 0 and NUM. OF SLAVE in section 3.3.3.3.4.
MASTER has two main functions:
(1) It issues commands to all SLAVE, such as voltage setting, current setting, protection
setting and etc., which means all settings in SALVE are from MASTER. The original
settings in SLAVE are temporary invalid.
(2) It accepts all measurement values and protection signals from SLAVE. The MASTER
calculates all measurement values and displays them in the main page. Moreover,
when protection is occurred in one SLAVE, the MASTER will notify other SLAVE to set
off the protection and show in the
MASTER’s main page.
When multiple DC Power Supplies are connected in series or parallel,
only one DC Power Supply can be the Master and the rest have to be
set to Slave.
Set MASTER as described below:
1. In Config Setup page,
press “
3
” and
ENTER
to select PARALLEL/SERIES
.
2. Use the numeric (
0
) key or “Rotary” (
) knob to set MASTER as Figure 3-39
shows.