Manual Operation
3-35
As to the voltage setting, the inputted analog voltage 0~5V maps to the actual output voltage
0~1200V; and for the current setting, the inputted analog voltage 0~5V maps to the actual
output current 0~25A as Figure 3-57(a) shows. Set the APG option to APG VSET/APG
ISET = Vref(0-10V) means the inputted analog voltage 0~10V maps to the actual output
0~1200V for APG voltage also maps to the actual output 0~25A for APG current as Figure
3-57(b) shows. For the above voltage/current setting method, the analog voltage (0~5V or
0~10V) has to be inputted to the devices connected in series respectively in order to have
the effect of serial operation in APG mode.
APG INPUT 5V/5V
D
C
S
O
U
R
C
E
O
U
T
P
U
T
1200V
/25A
APG INPUT 10V/10V
D
C
S
O
U
R
C
E
O
U
T
P
U
T
1200V
/25A
(a) (b)
Figure 3-57
3.3.3.6.2
Parallel Setting
To connect 5 sets of 62150H-600S DC Power Supplies in parallel for operation and set the
APG option to APG VSET/APG ISET = Vref(0-5V), the MAIN PAGE of MASTER will show as
Figure 3-58.
V = 6 0 0 . 0 0 _ V
∑ I = 1 2 5. 0 0 A M S T O F F
0 . 0 0 0 0 V 0 . 0 0 0 0 A
0 . 0 W
A P G
–
V S A P G
–
I S
Figure 3-58
As to the voltage setting, the inputted analog voltage 0~5V maps to the actual output voltage
0~600V; and for the current setting, the inputted analog voltage 0~5V maps to the actual
output current 0~125A as Figure 3-59(a) shows. Set the APG option to APG VSET/APG
ISET = Vref(0-10V) means the inputted analog voltage 0~10V maps to the actual output
0~600V for APG voltage also maps to the actual output 0~125A for APG current as Figure
3-59(b) shows. For the above voltage/current setting method, the analog voltage (0~5V or
0~10V) has to be inputted to the devices connected in series respectively in order to have
the effect of serial operation in APG mode.