Manual Operation
3-61
[ V O L T A G E C A L I B R A T I O N ]
R E M O V E E X T E R N A L L O A D A N D P R E S S [ E N T E R ] _
S E T T I N G O U T P U T V O L T A G E 8 . 0 0 V
A C T U A L
O U T P U T V O L T A G E = 0 . 0 0 0 0 V
S E T T I N G O U T P U T V O L T A G E 1 1 5 . 0 0 V
A C T U A L
O U T P U T V O L T A G E = 0 . 0 0 0 0 V
Figure 3-106
4.
When in Voltage calibration page, press “
ENTER
” to confirm.
5.
First does the low voltage range calibration, the instrument will output the voltage to
8.00V and the cursor is stopped at position [1] as Figure 3-107 shows. Enter the voltage
measured by DVM to position [1]
and press “
ENTER
” to confirm.
6.
Press “
” again to do the low voltage range calibration for its second point, the
instrument will output the voltage to 115.00V and the cursor is stopped at position [2] as
Figure 3-107 shows. Enter the voltage measured by DVM to position [2] and press
“
ENTER
” to confirm.
[ V O L T A G E C A L I B R A T I O N ]
R E M O V E E X T E R N A L L O A D A N D P R E S S [ E N T E R ]
S E T T I N G O U T P U T V O L T A G E 8 . 0 0 V
A C T U A L
O U T P U T V O L T A G E = 7 . 9 9 9 8 _ V
S E T T I N G O U T P U T V O L T A G E 1 1 5 . 0 0 V
A C T U A L
O U T P U T V O L T A G E = 1 1 4 . 9 8 V
[ 1 ]
[ 2 ]
Figure 3-107
7.
Press “
” to do the high voltage range calibration, the instrument will output the
voltage to 150.00V first and the cursor is stop at position [3] as Figure 3-108 shows.
Enter the voltage measured by DVM to position [3]
and press “
ENTER
” to confirm.
8.
Press “
” again to do the high voltage range calibration for its second point, the
instrument will output the voltage to 525.00V and the cursor is stopped at position [4] as
Figure 3-108 shows. Enter the voltage measured by DVM to position [4] and press
“
ENTER
” to confirm.
[ V O L T A G E C A L I B R A T I O N ]
R E M O V E E X T E R N A L L O A D A N D P R E S S [ E N T E R ]
S E T T I N G O U T P U T V O L T A G E 1 5 0 . 0 0 V
A C T U A L
O U T P U T V O L T A G E = 1 4 9 . 9 8 _ V
S E T T I N G O U T P U T V O L T A G E 5 2 5 . 0 0 V
A C T U A L
O U T P U T V O L T A G E = 5 2 4 . 9 8 V
[ 3 ]
[ 4 ]
Figure 3-108