Programmable DC Power Supply (with Solar Array Simulation) 62000H Series
Operating & Programming Manual
3-94
4.
Move the cursor to IRR and use the numeric keys (
0
~
9
) to set the
irradiation.
5.
Press “
ON/OFF
” will prompt a confirmation window as Figure 3-167 shows.
Figure 3-167
6.
Press
“
ON/OFF
” again to confirm the execution and it will go to the EN50530 MODE main
screen as Figure 3-168 shows. To quit, press
“
EXIT
” to return to the MAIN PAGE.
Figure 3-168
Figure 3-168 shows the screen when EN50530_MODE outputs. The EQ_VOC, EQ_VMP,
EQ_ISC and EQ_IMP are the actual operating points that are calculated based on the
settings set by the user of VMP and PMP via the hardware built-in formula.
Use
“
” and “
” to change the VMP and PMP parameters directly on the single
unit screen. When the parameter of VMP or PMP is change, use
“
” to move the
cursor to TRIG and press
“
ENTER
” to confirm the change. The IV curve will update
immediately and so too the EQ_VOC, EQ_VMP, EQ_ISC and EQ_IMP parameters.
3.3.9.5
SANDIA MODE
Chroma 62000H Series Programmable DC Power Supply (with Solar Array Simulation)
besides can simulate the solar cell curve via Solar Array Simulation Soft Panel, it also has
SANDIA_MODE built in to provide solar cell curve simulation function.
1.
Use the numeric
0
~
keys or rotary knob (
) to select SANDIA_MODE
as Figure 3-169 shows.
2.
Press
“
ENTER
” to confirm.