Remote Operation
5-49
SAS:SANDIA:TMP -100
Query Syntax:
SAS:SANDIA:TMP?
Return Parameter: <NRf+>
Query Example: SAS:SANDIA:TMP?
Return Example: -1.02
16. SAS:SANDIA:PMPp
Description:
It sets the PMPp in SANDIA Mode.
Syntax:
SAS:SANDIA:VMPp <NRf+>
Example:
It changes the PMPp of SANDIA to 1500.0 W.
SAS:SANDIA:PMPp 1500
Query Syntax:
SAS:SANDIA:PMPp?
Return Parameter: <NRf+>
Query Example: SAS:SANDIA:PMPp?
Return Example: 1.03
17. SAS:SANDIA:VMPp
Description:
It sets the VMPp in SANDIA Mode.
Syntax:
SAS:SANDIA:VMPp <NRf+>
Example:
It changes the VMPp of SANDIA to 500.0 V.
SAS:SANDIA:VMPp 500
Query Syntax:
SAS:SANDIA:VMPp?
Return Parameter: <NRf+>
Query Example: SAS:SANDIA:VMPp?
Return Example: 5.02
5.6.2.9
OUTPUT Subsystem
1.
OUTPut [: STATus]
Description:
It enables or disables the DC Power Supply output. To stop the
output is to set the output voltage to 0 volt.
Query Syntax:
OUTPut [: STATus]?
Parameter:
OFF | ON
Return Parameter: OFF | ON
2.
OUTPut : MODE
Description:
It sets the output mode and the general operating mode is
“CVCC”
Query Syntax:
OUTPut : MODE?
Parameter:
CVCC | TABLE |SAS
Example:
OUTPut:MODE CVCC
OUTPut:MODE TABLE
OUTPut:MODE SAS
Query Syntax:
OUTPut:MODE?
Query Example:
OUTPut: MODE?
Return Example:
CVCC or TABLE or SAS
TABLE Mode Setting Example:
OUTPut:MODE TABLE
IVCurve:EDIT <NR1>
IVCurve:VT {...}
IVCurve:IT {...}