Remote Sensing
2.4.1
Correct Connection
1.
Connecting remote sensing wire correctly can ensure the output voltage is the set
voltage. The DC Power Supply is able to compensate maximum 4% of F.S. line
voltage drop.
2.
Figure 2-6 shows the correct connection. Use two wires to connect the positive/negative
connector of load to the remote sensing connector on the rear panel. The connecting
wire diameter must be larger than 30AWG and its withstand voltage should be within the
specification.
3.
Though remote sensing is able to compensate the voltage drop; however, if the line loss
is too large (see specification) it will cause protection on remote sensing as Figure 2-8
shows and is unable to compensate voltage drop correctly.
4.
Connect the remote sensing wire of Model 62020H-150S as shown in Figure 2-7.
5.
The Remote sensing wire needs to be connected to the DC Power Supply local output
or the remote input of UUT.
Figure 2-6
Figure 2-7