Manual Operation
3-25
parallel mode.
2.
Do not connect the CURRENT SHARING cable when in series
operation or it could be malfunctioned or damaged.
3.
Do not connect the CURRENT SHARING cable when operated
standalone, or it could cause the power supply to be malfunctioned
or damaged.
4.
Be sure to remove the SYSTEM BUS and CURRENT SHARING
signal cables when returning to standalone operation or it could
cause the power supply to be malfunctioned or damaged.
3.3.3.3
Setting Series/Parallel Operation Mode
3.3.3.3.1
Setting SLAVE
CAUTION
It is necessary to set the SLAVE first and the MASTER last when
operating a 62000H Series DC Power Supply with Solar Array
Simulation in series or parallel mode, or it may not be able to operate
due to communication error.
When MASTER OR SLAVE sets to SLAVE, it has to set the SLAVE to SLAVE1 ~ SLAVE9
and M/S TERMINATOR selection. Set the SLAVE in sequence starting from SLAVE1.
1.
In Config Setup page, press “
3
” and “
ENTER
” to select PARALLEL /SERIES
and
display Figure 3-37.
2.
Use “
”, “
” keys to move the cursor to the PARALLEL OR SERIES
selection column.
[ S E R I E S / P A R A L L E L ]
M A S T E R O R S L A V E
= M A S T E R _
M / S T E R M I N A T O R = D I S A B L E
P A R A L L E L O R S E R I E S
= P A R A L L E L
N U M . O F S L A V E
= 1
M A S T E R & S L A V E C O N T R O L = N O
Figure 3-37
3.
Use the numeric (
1
~
9
) keys or “Rotary” (
) knob to set SLAVE1~SLAVE9
as Figure 3-38 shows.